Technical Specifications
Input Specifications
Input
Order code
Voltage
Model
Range
TIS 150-124 SIG
115/230VAC
TIS 150-148 SIG
selectable
TIS 300-124 SIG
by switch
TIS 300-148 SIG
93-132 VAC
187-264 VAC
TIS 300-124 SIG
(47-63 Hz)
TIS 300-148 SIG
Output Specifications
Regulation
- Input Variation (Line Regulation)
- Load Variation (Load Regulation)
Output Voltage ajustable Range
with Potentiometer
Ripple and Noise
(20MHz Bandwidth)
Electronic Current Limitation,
Short Circuit Protection (OCP)
Parallel Operation
Overvoltage Protection (OVP)
Hold-up Time
General Specifications
Operating Temperature Range
Storage Temperature Range
Load Derating above 50°C
Humidity (non condensing)
Switching Frequency
Safety class (according to IEC 536)
Case protection (according to IEC 529)
Safety Standards according to
Overvoltage category according to EN50178
Conducted EMI on the Input
Radiated EMI
Electromagnetic suspectibility
EMC Immunity
Environment
Connections and terminal assignment
Terminals
Function
L1 & N
Input Voltage (115/230VAC)
Protective Earth Conductor
+ & -
Output Voltage (24VDC)
Output
max.
Output-
Voltage
power
Factory Set ±50mV
24 VDC
150 Watt
48 VDC
24 VDC
300 Watt
48 VDC
24 VDC
600 Watt
48 VDC
V
- V
in min
in max
10% - 90% of I
out max
24 V Model
48 V Models
at V
und I
in nom
out max
Constant Current Limitation Characteristic
Triggerpoint at
all Models
Electrostatic discharge (ESD)
Electrical fast transients / Bursts
Immunity to conducted radio frequency disturbances
Connected load
use all terminals
Jenatschstrasse 1
Tel: +41 43 311 4511
CH-8002 Zürich
Fax: +41 43 311 4545
Input Current
Output
Current
at full load typ.
max.
115 VAC 230 VAC 115 VAC 230 VAC
6.0 A
3.0 A
1.7 A
3.0 A
12.0 A
5.4 A
3.3 A
6.0 A
24.0 A
10.5 A
6.4 A
12.0 A
-25°C - +70°C
-25°C - +85°C
%
2
/
°C
95% rel H max.
80 kHz typ. (PWM)
Class 1
IP20
 IEC / EN 60950
CB Scheme according to worldwide requirements
 UL/cUL 1950 recognised File No.: E181381
 UL 508 listed
 CSA22.2-14
Category III
EN 55022 Class B; EN 55011 Class B; FCC part 15
level B
EN 55022 Class A
IEC / EN 61000-4-2
RF field suspectibility
IEC / EN 61000-4-3
IEC / EN 61000-4-4
Surge
IEC / EN 61000-4-5
IEC / EN 61000-4-6
Mains frequency field
IEC / EN 61000-4-8
Vibration
IEC 60068-2-6
Shock
IEC 60068-2-27
Remarks
2
0.5 ... 6.0mm
Screw-type terminals
22 ... 10 AWG
Use a screwdriver with blade width of 3.5mm (0.1378in)
Recommended tightening torque 0.5 to 0.7Nm (4.5 to 6.2lb.in.)
E-Mail: techsupport@traco.ch
www.tracopower.com
Inrush Current
recommended
Circuit breaker
max. at +25°C (<2ms)
Characteristic C
35.0 A
70.0 A
10.0 A
35.0 A
70.0 A
15.0 A
70.0 A
80.0 A
20.0 A
±0.2% max.
±1.5% max.
24 - 28 VDC
48 – 52VDC
<50mVpp
110 % typ.
Automatic restart
not possible
140% typ. V
out nom.
30 ms min.
File No.: E181381
File No.: E181381
4kV / 8kV
10V / m
2kV
2kV / 4kV
10V
30A / m
1gn, 20 sweeps, each axes
15gn, 11ms, each axes
Date: April 20, 2011
Issue: 2.0
English
Efficiency
typ.
at 230VAC
84.0 %
88.0 %
87.0 %
89.0 %
88.0 %
90.0 %