DIL Switch Settings for Remote ON/OFF options
SW05 SW06 SW07 SW08 Description
Power supply OFF if pin1 and 2 (CON3) short circuit. Power supply ON if pin1 and 2 (CON3) open circuit. (Non-
OFF
ON
ON
ON
Isolated)
Power supply ON if pin1 and 2 (CON3) short circuit. Power supply OFF if pin1 and 2 (CON3) open circuit. (Non-
ON
OFF
ON
ON
Isolated)
Power supply OFF if voltage between +Remote ON and –Remote ON is >2.5VDC(
OFF
ON
OFF
OFF
if voltage between +Remote ON and –Remote ON is <1.0VDC. (500V Isolation)
Power supply ON if voltage between +Remote ON and –Remote ON is >2.5VDC(
ON
OFF
OFF
OFF
if voltage between +Remote ON and –Remote ON is <1.0VDC. (500V Isolation)
If other DIL Switch settings are accidentally set then the unit will NOT be damaged but correct operation is NOT guaranteed.
TIS 150-1xx SIG Board
Mains OK
DIL Switch (SW01 to SW08)
ON
OFF
Potentiometer
R19
TIS 300-1xx SIG Board and TIS 600-1xx SIG Board
Potentiometer
R19
DIL Switch (SW01 to SW08)
OFF
DC OK
1 2
3
5 6 7
4
8
ON
1 2
3
5 6 7
4
8
Jenatschstrasse 1
Tel: +41 43 311 4511
CH-8002 Zürich
Fax: +41 43 311 4545
DC-Output
LK01
LK02
LK03
LK01
LK02
LK03
E-Mail: techsupport@traco.ch
www.tracopower.com
English
English
). Power supply ON
60VDC max
). Power supply OFF
60VDC max
Date: April 20, 2011
Page
Issue: 2.0
Seite
7