KPS PA70 Manuel D'instructions page 36

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

3.2.7.3 Through mode HZ/DUTY:
Measuring range
9,999Hz
99,99Hz
999,9Hz
9,999kHz
99,99kHz
999,9kHz
9,999MHz
- Overload protection: 250V DC or AC (RMS)
- The input voltage range: > 2V (input voltage will increase when the frequency
to be measured increases).
3.2.8 Duty Radio
Measuring range
0,1 – 99,9%
Through mode A (from clamp head):
- Frequency response: 10~1kHz
- Input current range: > 20A AC (RMS)
- Maximum input current: AC 1000A
Through mode V:
- Frequency response: 10~10kHz
- Input voltage range: > 60mV AC
- Input impedance: 10MΩ
- Maximum input voltage: 750V AC (RMS)
Through mode HZ/DUTY:
- Frequency response: 10 ~ 10MHz
- The input voltage range: > 2V AC (RMS) (input voltage will increase when the
frequency to be measured increases)
- Maximum input voltage: 250V AC (RMS)
KPS-PA70 • Digital clamp meter
Resolution
0,001Hz
0,01Hz
0,1Hz
0,001kHz
0,01kHz
0,1kHz
0,001MHz
Resolution
0,1%
36
Accuracy
±(0.3% reading + 5 digits)
Accuracy
±3,0%