In some cases, the pump and the pumping medium may be hot
and could cause burns.
For installations in areas subject to explosion hazards, special
regulations apply!
APPLICATION
The WCfix 260 is a sewage disposal unit for a toilet above and
below the backpressure level.
• There should only be a few users and there must be an ad-
ditional toilet available above the local back-flow level.
• Only domestic wastewater without hazardous substances
according to EN 12056 can be discharged.
• The unit is operated in combination with a cistern with a ca-
pacity of at least 6 litres. If the amount of flush water is less
than 6 litres, for example due to water-saving buttons, then
we cannot guarantee that the unit will work properly.
A washbasin, a shower and a bidet can also be connected.
These additional facilities must be installed in the same room.
The standard EN 12050-3 does not permit any other additional
facilities, such as a washing machine, sink, dishwasher or bath,
to be installed.
If installed in compliance with the regulations and used for the
intended purpose, then this appliance meets the protective re-
quirements of the EMC directive 2014/30/EU and is suitable for
domestic use and connection to a mains power supply.
It can be used wherever the installation of a toilet is required as
part of renovation or conversion work. The faecal matter and
toilet paper are conveyed by the pump to existing collecting
tanks.
NOTICE! However, sanitary articles, paper towels, moist toilet
paper, leftovers, solvents, chemicals, grease etc. must not be
disposed of in the toilet.
The flow rate in the pressure pipe must be at least 0.7 m/s.
The limitation of use due to the maximum delivery head is 0.4
bar (4.0 m of water).
The resulting geod. delivery head and range, depending upon
the pipe diameter, is shown in figure 2. The permissible me-
dium temperature is 35° C, the operating mode is intermittent
duty S3, 30% (3 min. operation - 7 min. interval)
NOTICE! When the unit is installed in bathrooms and shower
rooms VDE regulations 0100 part 701 must be complied with!
The WCfix 260 is frost-resistant to -20°C when stored in dry
conditions. Once installed, however, the residual water in the
toilet must not be allowed to freeze.

Scope of supply

1 complete WCfix 260, 1 non-return valve 1¼", 1 discharge elbow
d=32, 2 connection sleeves d=40, 1 "Prohibited substances"
sticker, 2 wood screw 4x40, 2 rawlplug S6, 1 active carbon fil-
ter, 2 pipe clips, drill template, this manual.

ELECTRICAL CONNECTION

WARNING!
The WCFIX 260 must only be connected to sockets that have
been installed properly in accordance with the regulations and
and are protected with at least 10 A (slow) and FI-safety switch-
es (30mA)
NOTICE! Only qualified electricians may carry out electrical
works to the WCFIX 260.
NOTICE! Never put the mains plug in water! If water gets into
the plug, this can cause malfunctions and damage.
The relevant standards (such as EN standards), country-spe-
cific regulations (such as VDE in Germany), and the regulations
of the local power supply companies must be observed.
Observe the operating voltage (see the type plate)!
No additional motor protection is required, since the system
has an integrated coil thermostat.
Unacceptably high temperatures and long periods of continu-
ous operation cause the thermostat to shut down the motor.
WARNING!
After the thermostat has switched off the system, pull out the
mains plug before remedying the fault, since the device can
switch itself on again automatically if the power is still con-
nected.
General explication
The WC-fix 260 operates automatically depending on the wa-
ter level in the tank.
INSTALLATION
The WCfix can be fixed directly at commercial toilets (DIN 1387
or 1388) with a horizontal discharge pipe. The height of the in-
stallation level up to the middle of the connection piece must
be 180 mm.
NOTICE! A connection tube between the WCfix and the toilet
can cause malfunctions.
This sort of installation is not in accordance with the rules of
the German institute for construction engineering.
The required space behind the toilet is the same as the one of
a commercial flushing box with a content of 9l. The distance
between the end of the connecting branch of the toilet and the
wall must have a minimum of 275 mm, to allow a removing of
the unit without demounting the basin. The enclosed flap-trap
must be installed into the pressure tube (preferred installa-
tion: vertical, connection 1¼ inch). We recommend installing a
shut-off valve after the check valve in the pressure pipe. This
allows the check valve to be serviced easily. If the pressure
pipe is installed entirely horizontally to the collecting or main
pipe, a stagnation loop must be installed in the pressure pipe.
If the pressure pipe is installed with the pressure pipe transi-
tion point located below the system installation level, then
the pressure pipe must be enlarged after its highest point by
a wider-dimensioned pipe to prevent any suction lifting effect
from being created which would cause the tank to empty au-
tomatically.