European Technical Assessment
ETA-11/0492
3.4
Safety in use (BWR 4)
The essential characteristics regarding Safety in use are included under the Basic Works
Requirement Mechanical resistance and stability.
3.5
Protection against noise (BWR 5)
Not applicable.
3.6
Energy economy and heat retention (BWR 6)
Not applicable.
3.7
Sustainable use of natural resources (BWR 7)
The sustainable use of natural resources was not investigated.
3.8

General aspects

The verification of durability is part of testing the essential characteristics. Durability is only
ensured if the specifications of intended use according to Annex B are taken into account.
4
Assessment and verification of constancy of performance (AVCP) system applied, with
reference to its legal base
According to Decision of the Commission of 24 June 1996 (96/582/EC) (OJ L 254 of 08.10.96
p. 62-65), the system of assessment and verification of constancy of performance (see Annex V
and Article 65 Paragraph 2 to Regulation (EU) No 305/2011) given in the following table applies.
Product
Metal anchors for use in
concrete (heavy-duty
type)
5
Technical details necessary for the implementation of the AVCP system, as provided for
in the applicable European Assessment Dcoument
Technical details necessary for the implementation of the AVCP system are laid down in the
control plan deposited at Deutsches Institut für Bautechnik.
Issued in Berlin on 26 June 2014 by Deutsches Institut für Bautechnik
Gerhard Breitschaft
President
Z39695.14
Page 4 of 22 | 26 June 2014
Intended use
For fixing and/or supporting
concrete structural elements or
heavy units such as cladding and
suspended ceilings
Level or class
Beglaubigt:
Baderschneider
System
1