MANUAL OPERATION (WITHOUT REMOTE)

How to operate your unit without the remote control.
2
In the event that your remote control fails to work, your unit can be operated manually with the MANUAL
l Operation (Without Remote)
CONTROL button located on the indoor unit. Note that manual operation is not a long-term solution, and
that operating the unit with your remote control is strongly recommended.
ate your unit without
CAUTION
G
ontrol
The manual button is intended for testing
BEFORE MANUAL OPERATION
our remote control fails to
purposes and emergency operation only. Please
n be operated manually with
do not use this function unless the remote control
NTROL button located on
Unit must be turned off before manual operation.
is lost and it is absolutely necessary. To restore
ote that manual operation is
regular operation, use the remote control to
lution, and that operating
activate the unit.
remote control is strongly
To operate your unit manually:
AL OPERATION
ed off before manual
1 . Locate the MANUAL CONTROL button on the right-hand side panel of the unit.
it manually:
Manual control button
2 . Press the MANUAL CONTROL button one time to activate FORCED AUTO mode.
NUAL CONTROL button on
ide panel of the unit.
3 . Press the MANUAL CONTROL button again to activate FORCED COOLING mode.
UAL CONTROL button one
FORCED AUTO mode.
4. Press the MANUAL CONTROL button a third time to turn the unit off.
UAL CONTROL button again
CED COOLING mode.
UAL CONTROL button a third
unit off.
CAUTION
The manual button is intended for testing purposes and emergency operation only. Please do not
use this function unless the remote control is lost and it is absolutely necessary. To restore regular
operation, use the remote control to activate the unit.
F

OPTIMAL OPERATION

To achieve optimal performance, please note the following:
Adjust the air flow direction correctly so that it is not directly directed to people.
Adjust the temperature to achieve the highest comfort level. Do not adjust the unit to excessive tem-
perature levels.
Close doors and windows otherwise the desired effect may be reduced.
Do not put any object near air inlet or air outlet, as the efficiency of the air conditioner may be
reduced and the air conditioner may stop running. Make sure there are no obstacles blocking the air
flow. The air stream must be allowed to reach the entire room unhindered. Also the air stream must
be allowed to reach the air conditioner unhindered.
Clean the air filter periodically, otherwise cooling or heating performance may be reduced. It is
advised to clean the filters every two weeks.
Do not operate unit with horizontal louvre in closed position.
4
58
58
G

ADJUSTING AIR FLOW DIRECTION

Adjust the air flow direction properly otherwise, it might cause discomfort
or cause uneven room temperatures.
Adjust the horizontal louver using button h on the remote controller.
Adjust the vertical louver manually.
Adjusting the horizontal Air Flow Direction (up - down)
The air conditioner automatically adjusts the horizontal air flow direction in accord-
ance with the operating mode.
To set the horizontal air flow direction
Perform this function while the unit is in operation. Keep pressing the AIR DIRECTION
button h on the remote controller to move the louver to the desired direction.
Lever
Adjust the horizontal air flow direction to the desired direction.
In subsequent operations, the horizontal air flow is automatically set in the
direction to which you adjusted the louver by pressing the AIR DIRECTION
button.
To set the vertical air flow direction (left - right)
Adjust the vertical louver manually using the lever in the middle of the vertical
louver arm (depending on model). When the air conditioner is in operation and the
vertical louver is in a specific position, move the lever at left (or right, depending
on model) end of the air outlet to the desired position.
CAUTION!
Take care, do not touch the fan behind the vertical louvers!
To automatically swing the air flow direction (up - down)
Perform this function while the air conditioner is in operation.
Press the SWING g button on the remote controller.
To stop the function, press the SWING button g again. Press AIR DIRECTION h button to lock louver in
desired position.
CAUTION
• The AIR DIRECTION and SWING buttons will be disabled when the air conditioner is not in
operation (including when the TIMER ON is set).
• Do not operate the air conditioner for long periods with the air flow direction set downward
in cooling or dry mode. Otherwise, condensation may occur on the surface of the horizontal
louver causing moisture to drop.
• Do not move the horizontal louver manually. Always use the AIR DIRECTION h or SWING
button g. If you move this louver manually, it may malfunction during operation. If the louver
malfunctions, stop the air conditioner once and restart it.
• When the air conditioner is started immediately after it was stopped, the horizontal louver
might not move for approximately 10 seconds.
• Do not operate unit with horizontal louver in closed position.
4
59
59