For connections, interrupt the loop and use the same wires to connect to the detector.
Inputs may be programmed as NC, NO, single balance and double balance. Both inputs can manage fast
signals from seismic or roller blink sensors. Connection mode is NC type fixed in this case.
WARNING: "Double balance" is the only EN50131 compliant connection mode. Refer to the manuals of
1067 and 1068 series control panels for further, more detailed information.
DEVICE ACQUISITION
KEY CUSTOMISATION
Key customisation may be useful, for example, to associate a key with limited operation. The key can be
rapidly identified by inserting the colored bulbs provided in the kit Ref. 1067/334 in the seats on the key.
TECHNICAL SPECIFICATIONS
Rated supply voltage (picked by the control panel through the bus) ................................................ 13.8 Vcc
Operating voltage min/max .................................................................................................... 9 Vcc ÷ 15 Vcc
Rated current absorption at 12 Vcc:
LEDs OFF ....................................................................................................................................... 7 mA
All LEDs ON .................................................................................................................................. 10 mA
Auxiliary inputs ........................................................................................................................................... 2
Degree of protection of casing ..................................................................................................... IP40 / IK02
Operating temperature............................................................................................................. -5°C +45°C
Dimensions (W x H x D) ..................................................................................................... 50 x 40 x 22 mm
4
The reader can be acquired by pressing the dedicate button.
For details on the acquisition procedure, refer to the control panel installation
manual.
To display the reader address, press the button and count the blink of the yellow
LED.
EN50131
DS1067-083B