disassembled parts in the cleaning solution.
ATTENTION
When cleaning the machine, dump it, do not allow exces-
sive amounts of water around the electrically operated
components of the unit. Electrical shock or damage to
the machine may result.
3
Do not immerse the lighted top covers in liquid. Wash them
apart with the cleaning solution. Carefully clean their
undersides.
4
In the same manner clean the evaporator cylinder(s) using
a soft bristle brush.
5
Rinse all cleaned parts with cool clean water.
5. 3. 3 SANITIZING
Sanitizing should be performed immediately prior to
starting the machine. Do not allow the unit to sit for
extended periods of time after sanitization.
1
Wash hands with a suitable antibacterial soap.
2
Prepare at least two gallons of a warm (45-60 °C 120-
140 °F) sanitizing solution (100 PPM available chlorine
concentration or 1 spoon of sodium hypoclorite diluted with two
litres of water) according to your local Health Codes and
manufacturer's specifications.
3
Place the parts in the sanitizing solution for five minutes.
4
Do not immerse the lighted top covers in liquid. Carefully
wash their undersides with the sanitizing solution.
5
Place the sanitized parts on a clean dry surface to air dry.
6
Wipe clean all exterior surfaces of the unit. Do not use
abrasive cleaner.
5. 3. 4 ASSEMBLY
1
Slide the drip tray into place.
2
Lubricate faucet piston, inside auger and outer spiral (see
points A, B and C of figure 12) only with the grease supplied by
the manufacturer or other food grade approved lubricant.
3
Assemble the faucet by reversing the disassembly steps
(see figure 11)
4
Fit bowl gasket around its seat.
Note: the largest brim of gasket must face against the rear wall
figure 12
(see figure 13).
5
Insert the auger into the evaporator taking care to
accompany it to the end so as to prevent it from hitting against
the rear wall (see figure 14).
6
Install the outer spiral. Slide it over the evaporator until its
front notch engages with the exposed end of the auger shaft
(see figure 15).
7
Push the bowl towards the rear wall of the unit until it fits
snugly around the gasket and its front fastening hooks are
properly engaged (see figure 16).
8
Use fresh product to chase any remaining sanitizer from the
15
figure 13
figure 14
figure 15
figure 16