Télécharger Imprimer la page

Main Switch - Tylo Tylette Sector Instructions De Montage Et D'emploi

Publicité

Les langues disponibles
  • FR

Les langues disponibles

Let your body dry slowly in the warm air before starting to get dressed. Sit
without clothes until your skin has cooled down and the pores have closed.
Treat yourself to a long, cool drink, sit back and enjoy life.
Cleaning Tylette
Each time you have used the steam bath, rinse the seats and floor with warm
water. (Do not use a high-pressure hose). Wash the seats at regular intervals
with a mild soapy solution. For day-to-day disinfecting we recommend Tylö
Steam Clean which works fully automatically. It is important that steam room
floors are cleaned thoroughly, right into the corners. Use hot water, a
scrubbing brush and a floor cleaner that lifts off grease and grime.
Plumbing installation.
A qualified plumber must carry out plumbing work.
Connecting the water: Connect the hot and cold water supply to the Tylette
connection hoses.
IMPORTANT! The pipes must be flushed clean before connecting the
incoming water supply to the Tylette.
This prevents swarf and other impurities from the pipes from entering the
generator.
Electrical installation.
Electrical work is to be carried out only by a qualified electrician using the built-
in relay box (see wiring diagram). The internal connections between the relay
box, steam generator and solenoid valves are fitted prior to delivery. Connect
the lighting to the terminal box located on the roof dome, using the cable
connected to the isolating transformer.
The Tylette is powered via a cable direct from the distribution box. Do not fit a
switch or contactor along this cable. (Please refer to the section 'Automatic
Emptying'.)
UK: Do not forget to earth the equipment.
Lighting.
Can be regulated by a control panel.
Connection to a central computer
The unit can also be connected to a central controlling computer which sends
a short impulse between terminals 19 and 20 on the CC-Tylette.
Operation.
Functions.
1 = Lightning. 2 = ON/OFF. 3 = Temperature setting. 4 = Time setting.
5 = Reduce temperature/time. 6 = Increase temperature/time 7 = Display.
Lighting
The lighting switches on and off automatically together with the steam
generator, or can be controlled manually by pressing the LIGHT button.

Main switch

There is a main switch on the underside of the steam generator, which should
only be used if the equipment is to be switched off for a lengthy period of time.
The CC panel's memory function ceases to work if the power supply to the
unit is interrupted.
Settings.
6
Setting the bathing temperature.
Press TEMP – the previous temperature is displayed. Use the up and
down arrows (
) to change the temperature.
Manual on/off.
Press ON to switch the facility on. Press OFF to switch it off. (the LED
goes out). If you forget to switch off the generator manually, it switches
off automatically after 3 hours.
Timer settings.
(The steambath must be switched off)
Press TIME (the hour digits blink) – set the number of hours until you
want to use the steam bath using the up and down arrows (
Press TIME (the minute digits blink) – set the number of minutes until
you want to use the steambath using the up and down arrows (
(Important: The hour or minute digits must be blinking before you press
ON).
Press ON – the on time is activated and a red LED blinks until the
generator automatically starts after the pre-set time. The heater
switches off automatically after 3 hours.
You can switch off the generator manually at any time by pressing OFF.
Code lock to prevent settings from being changed.
First program as above, then wait at least 20 seconds. Press on the down
arrow ( ), hold it down and press TEMP and TIME at the same time. The
code lock, which prevents all changing of settings, is now activated. To return
to unlocked mode, press the down arrow ( ), hold it down and press OFF at
the same time.
Code lock that only prevents changing of the temperature setting.
First program the temperature as above, then wait at least 20 seconds. Press
TIME, hold it down and press TEMP and LIGHT at the same time. The code
lock, which prevents changing of the temperature settings, is now activated.
To return to unlocked mode, press the down arrow ( ), hold it down and
press OFF at the same time.
Checklist for faults.
WARNING! SEVERAL SUPPLY CIRCUITS. CHECK THAT THERE IS
NO CHARGE IN THE MACHINE BEFORE DOING ANY
MAINTENANCE WORK!
Initial checks
In the event of any malfunction, check:
that the Tylette cabinet has been correctly wired in accordance with the
wiring diagram.
that the water filter is clean. (The filter is fitted to the connection for incoming
water. To clean the filter, disconnect the pipe joint, remove the filter and free
it from any limescale and other particles that have accumulated.)
that the tap (if fitted) on the water pipe to the steam generator is not closed.
that all the fuses in the fuse box are intact (or, if you have circuit breakers,
that none has been triggered).
that the control panel setting is correct.
that the inbuilt temperature limit control has not been activated.
that the ventilation complies with our recommendations.
TYLÖ AB, Svarvaregatan 6, S-30250 Halmstad, Sweden.
Phone 035-10 00 80, Fax 035-102580.
E-mail: info@tylo.se, Internet: www.tylo.se
© This publication many not be reproduced, in part or in whole, without the written permission of Tylö.
Tylö reserves the right to make changes in materials, construction and design.
).
).

Publicité