Electrical Installation
All model ovens on the front cover are dual rated,
designed to be connected to either 208/240V AC,
60 Hz, 4 wire, single-phase power supply.
Model
ME301JP,
ME301JS,
MED271JS,
MED301JS,
MED301JP,
POD301J
ME302JP,
ME302JS,
MED272JS,
MED302JS,
MED302JP,
PODC302J
MEDMC301JS,
MEDMC301JP,
MEDMCW71JS,
MEDMCW31JP,
MEDMCW31JS,
PODM301J,
PODMW301J
The electrical supply should be a 4-wire single-phase AC.
Install a suitable conduit box (not furnished). An
appropriately-sized, UL-listed conduit connector must be
used to correctly attach the conduit to the junction box.
NOTICE: Local Codes may vary; installation, electrical
connections and grounding must comply with all
applicable local codes.
If local codes permit grounding through the electrical
supply neutral, connect both the white neutral wire and
the bare ground wire from the oven to the white neutral
electrical supply wire.
8
Circuit Required
30 AMP
40 AMP
50 AMP
Electrical Connection
The four-wire connection is preferred, but where local
codes permit, the three wire connection is also
acceptable.
Four-wire Connection
1
Cable from power supply
2
White wires
3
Black wires
4
U.L.-listed conduit connector
5
Cable from oven
6
Bare or green wires
7
Red wires
8
Junction box
Connect the red oven wire to the red electrical supply
▯
wire (hot wire).
Connect the black oven wire to the black electrical
▯
supply wire (hot wire).
Connect the white neutral oven wire to the white
▯
neutral (not bare ground) electrical supply wire.
Connect the oven bare ground wire to the bare (or
▯
green) electrical supply ground wire.