4. Installation
4.1
GB
Checking the clearance and the required the installation space
≥ 350
(450*)
•
Use the sealing profile for the top side as a connection between the vertical gui-
de rail columns (this also serves to check the distance of the internal width).
•
For this purpose lay the sealing profile on the ground.
* With cover
10
≥ 650 (700*)
≥ 250
(350*)
X
X
4.2
Attaching the column to the driving side
X
•
Place the column with the driving side on the ground to match the
width of the sealing profile and set it upright.
•
Remove the screws from the cover and fold open the column.
•
Attach the column provisionally to the door frame with two glue
clamps.
•
Measure a user-defined height of the sealing profile (X) on to the
column (see illustration).
GB
11