4. Installation
4.1
GB
Determine the location for the base plates. The distance between the
base plates must be equal to the clear width (C) on the order form.
Note: this may vary from the actual clear width!
NOTE! CENTERED AGAINST THE MIDDLE OF THE OPENING!
4.2
Max. 3
Determine the number of shims on the basis of the difference between HL and HR
(see paragraph 2.9).
8
4.3
20 Nm
Mount the floor plates.
4.4
Position the first
column.
GB