• Installation Instructions
Please read these instructions carefully prior to
installation!
Installation should only be carried out by persons
qualified to do so!
Incorrect installation can put the safety of persons at
risk!
In case of improper installation, the manufacturer's
guarantee becomes void.
Preparing for installation
1. To connect to the mains, a power point must be
installed on site - the included mains lead is
approx. 1 m long.
2. Check the stability of the door, retighten the
screws and nuts on the door.
3. Check that the door is running smoothly and is
in good working order, lubricate the shafts and
bearings. Check the pretension of the springs
and, if necessary, re-adjust.
4. Dismantle the existing door latches (bolt plate
and catches).
5. For garages without a second entrance, an
emergency release is required (accessory).
6. If a wicket door is included, fit the wicket door
contact.
7. Check the supplied screws and wall plugs to
ensure that these are suitable for the structural
conditions on site.
0
Required tools
- Drilling machine with 6 mm masonry drill
- Sturdy side cutter
- Wrench, sizes 13, 15 and 17 mm
- Slotted screwdriver, 3 mm wide
- Phillips screwdriver, size 2 x 100 mm
1
Choosing the installation side
Choose the installation side in accordance with the
structural conditions on site. The standard
installation side is on the right (as viewed from the
inside). For special installation situations
see
.
25
Spray the track with silicone to achieve optimum
running qualities.
2
Fitting the toothed belt
The top door track is used for installing the drive unit.
Place the toothed belt with prefitted end clamp in the
track (back of toothed belt facing upwards).
end clamp with hook onto vertical formed end piece.
2b
To disengage the drive wheel, actuate the lever.
Feed the toothed belt through the drive wheels of the
motor head as shown.
2c
Insert drive unit with the drive wheels into the top
track.
2d
Inserting the limit stop.
Position the limit stop at a distance ordering height +
50 cm from the frame under the toothed belt.
The limit stop should stop the operator approx. 5 cm
above the desired open position.
Finally, push end of toothed belt through the opening
in the end assembly angle.
3
Fitting the rear toothed belt fastening
3a
Feed the toothed belt through the end assembly
angle and keep it taut.
Slot sleeve halves, as shown in
toothed belt.
Attach knurled nuts
3d
and turn to tension the
toothed belt by hand.
3e
Make sure that you do not twist the toothed belt
in the process.
3f
If the toothed belt overhangs, it can be
shortened.
4
Inserting the top track roller
4a 4b
+
Remove the track roller's extension ring
Retain these installation, operating and maintenance instructions for the full duration of the operator's service life!
4c
Insert the track roller into the track, adjust and
screw in place in accordance with the figure shown.
5
Fastening the door bracket
Place the door bracket on the designated drill holes
of the top door leaf section and screw down with 3
self-tapping screws 6.3 x 16.
6
Inserting the lifting arm
6a
Slot the lifting arm onto the bolt of the motor head
and secure with clip.
6b
Hold the other side of the lifting arm between the
door bracket and select hole setting (VL setting for
construction years prior to 2006).
6c
Push the bolt all the way through and secure with
clip. Connect door to operator.
7
Sliding block
Slot the sliding block onto the track profile, push into
the rear opening on the motor head and screw down
with screw 4.2 x 13.
8
Mains lead cable
The back of the control unit includes a chamber
where, if required, the excess mains lead can be
stowed
8b
.
9
Connecting the coiled cable
9a
At the back of the control unit there is a cable
terminal for the two individual wires.
9b
Insert red wire on left (1) and green wire on
right
(2)
into the terminal.
9c
Insert plug (3) into designated socket and allow
to engage.
9d
Afterwards, feed the cable through labyrinth.
10
Fastening the control unit
10a
Install the control unit onto the side wall. At a
distance of approx. 1m from the door and 1.50m from
the floor, mark the spot for the first plug hole, drill the
hole, insert the plug but do not screw in fully. Place
the control unit with key hole onto the screw head.
10b
Align the unit and mark the remaining fixing
holes, drill holes, plug and fasten with screws
4.2 x 32.
11
Wall clamp
Hold up the coiled cable in a vertical position. The
maximum extension of the horizontally routed cable
may not exceed three times the original length.
Attach the wall clamp at the bend. Hold the clamp
2a
Slot
against the wall, mark the spot, drill, plug and screw
to the wall using screw 4.2 x 45.
12
Connecting plan / aligning the aerial
Instructions
!
current-carrying cables, only connect volt-
free push buttons and volt-free relay
outputs.
Where door systems are used by the
public or are impulse-operated out of sight
of the door, a photocell must be installed.
E. Connection for aerial
Route the aerial on the housing exit upwards.
When using an external aerial, the shielding
must be assigned to the adjacent terminal (F, on
3b/3c
, onto the
right)
12b
.
F. Connection for external impulse generator
(accessories, e.g. key switch or digital coder)
G. Input STOP A
Connection for safety devices
(accessories, e.g. wicket door contact).
An interruption at this input end causes the door
to stop during the opening or closing phase or
prevents the operator from starting up in either
direction. Connection for safety devices
8a
,
:
Do not connect any
12b
12c
(accessories).
H. Input STOP B
An interruption at this input end causes the
operator to automatically change direction
during the closing phase only.
Connection for 2 wire light barrier EXTRA 626
12d
(accessories).
Connection for an optical closing edge
12e
protection OSE
.
I. Voltage supply 24 V ~
Connection can take a max. load of 100 mA
(do not exceed!).
Connection for 24V signal lamp
(accessories). Connection for an external
receiver
12g
(accessories).
J. Plug-in base for radio receiver
K. Connection for an external light, protected light
or signal lamp (protection classification II, max.
500W)
12h
(accessories).
• Warning sticker
Place the sticker clearly visible on the inner surface
of the door.
13
Lamp shade
13a
The lamp shade conceals the terminal
connections. To do this, feed the back part of the
lamp shade underneath the guides of the control
unit.
13b
Fasten the lamp shade with two self-tapping
screws 4.2 x 16.
14
Control elements
14a/b
The control elements for programming the
door operator are located behind the white cover.
The cover can be opened with a screwdriver.
Once the operator has been programmed, the cover
is reclosed and serves as an interior push-button
A. The numerical display serves to indicate the
menu stage, the respectively set value and the
error/fault diagnosis.
a. The incremental display, lights up to indicate
readiness for operation and flashes on
acknowledgement of learned hand transmitter
codes.
B. During the setting / adjustment phase button
serves as an "UP" button and outside the menu
as a START button.
C. During the setting / adjustment phase button
serves as a "DOWN" button.
D. Button
serves to call up the settings /
adjustment menu, to change the menu stages
and store the settings.
Programming the control unit is menu-driven.
Pressing button
, calls up menu prompting. The
numbers displayed indicate the menu stage. After
approx. 2 seconds, the display flashes and the
setting can be altered via buttons
selected setting is stored via button
programme automatically jumps to the next menu
stage. By repeatedly pressing the button
stages can be skipped. To quit the menu, repeatedly
press button
until "0" is displayed again. Outside
the menu, button
can be used to generate a start
impulse.
15
Menu stage 1: Programming the start
function for the hand transmitter
Briefly press button
. "1" is displayed. As soon as
the display flashes, press and keep pressed for
approx. 1 second the button of the hand transmitter,
GB
12f
23
.
and
. The
and the
, menu