Button Assignment - SSS Siedle Basic SET CVB 850-1 E/W Information De Produit

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 20
Specifications CV 850-...-03
Colour system: PAL
Image pick-up: CMOS sensor 1/3"
756 x 504 Pixel
Resolution: 550 TV lines
Lens: 3,7 mm
Pick-up angle: horizontal appr. 65°,
vertical appr. 50°
Mechanical adjustment range:
30° horizontal/vertical
Integrated LED lighting
2-step heating:
12 V AC, max. 110 mA
Supply: via In-Home bus
Contact type: contact 24 V, 2 A
Protection system: IP 54, IK 8
Ambient temperature:
–20 °C to +40 °C
Dimensions (mm) W x H x D:
82 x 226 x 35
Specifications VIB 150-...
Operating voltage: via In-Home bus
Operating current: on supply via
+M/–M max. 300 mA
Dimensions (mm) W x H x D:
135 x 115 x 24
Specifications SNG 850-...
Operating voltage:
230 V AC, +/-10 %, 50/60 Hz
Operating current: 200 mA
Output voltage: 27.5 V DC, 12 V AC
Output current: 0.5 A DC, 1 A AC
Fusing: Primary fuse 1 T 250 mA L,
secondary short circuit proof
Contact type: 2 n.o. contacts 24 V,
2 A
Protection system: IP 30
Ambient temperature:
0 °C to +40 °C
Horizontal pitch (HP): 9
Dimensions (mm) W x H x D:
162 x 89 x 60
16
Plug+Play programming
Basics
Plug+Play programming offers
the simplest opportunity for those
without programming experience
to commission the set. The entire
installation of all users must have
been completed.
The housings of the indoor stations
must not yet have been closed. The
Plug+Play mode must be activated
on the SNG 850-... line rectifier. The
top call button of the door station
is always assigned to the first indoor
device.
Conditions for Plug+Play:
• Install the system in accordance
with the wiring diagram
• Connect the base plates of the
indoor devices, do not yet close the
housings
• At the door station, inscribe the
assignment of call buttons if possible
straight away.
• Set the SNG 850-... to the
Plug+Play mode by holding down
the programming mode button for
5 seconds. LED 1 must light up con-
tinuously.
• Attach the indoor devices to the
base plates in the same order as the
call buttons are assigned.
• The storey call briefly sounds as an
acknowledgement. The next indoor
device can be closed.
• After all the indoor devices have
been closed, press the programming
mode button on the SNG 850-...
The programming mode is switched
off, the programming of the system
is complete.
Reset Plug+Play
In the event of a failed programming
attempt, Plug+Play programming
can be carried out again.
• Switch off the supply voltage.
• Remove all telephones from the
base plates.
• Switch the supply voltage back on
again and wait until the SNG 850-...
is in normal operating mode (approx.
1–2 minutes)
• Set the SNG 850-... to the
Plug+Play mode by holding down
the programming mode button for
5 seconds.
• Hold down the programming
button at the door station for 4 sec-
onds until an acknowledgement
tone is audible.
• Plug+Play programming can now
begin again.
Prog.

Button assignment

Upper button = Indoor device 1
Lower button = Indoor device 2

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Basic set cvb 850-2 e/w

Table des Matières