6 Putting into operation

Closing the dust collecting bag tightly
4
Removing the filter cartridge
Fig. 6
9 Remove the filter cartridge (5) and slide it completely into the dust collecting bag.
10Close the dust collecting bag tightly.
11 Clean the sealing surface of the cover using a damp disposable cloth.
12 Dispose of the dust collecting bag and the disposable cloth according to the local regulations.
 12 Disposal on page EN-21
NOTICE
• When mounting the new filter cartridge, make sure to touch only the bottom of the filter. Otherwise the
13 Place the pin and the sponge rubber seal of the new filter cartridge (5) into the locking mechanism.
14 Press the filter cartridge (5) slightly downwards into the locking mechanism.
15 Fix the filter cartridge (5) by turning it to the right (clockwise direction).
16 Make sure that the filter cartridge is fixed on all locking points.
NOTICE
• Make sure that the cables and hoses are not kinked, caught or damaged.
17 Insert the cover with the mounted new filter cartridge into the fume extraction system.
18 Tighten the fastening screws (3).
6 Putting into operation
Risk of injury due to unexpected start-up
For the entire duration of maintenance, servicing, mounting, dismounting and repair work, the following
instructions must be adhered to:
• Switch off the power source.
• Pull the mains plug.
NOTICE
• The fume extraction system must be mounted on a plane surface near the work area.
EN - 14
Inserting a new filter cartridge into the
5
locking
filter material may become damaged, which will destroy the filter cartridge.
DANGER
FES-200 W3
Checking the locking points