5 Functional Description
Proceed as follows:
 Fig. 2 Functional Description on page EN-9
1 Place the fume extraction system on the floor.
2 Switch off the fume extraction system by actuating the rotary switch (11).
3 After having switched off the fume extraction system, wait (for approx. 1 minute) until the dust has settled
down in the fume extraction system.
4 Remove the suction hose from the air intake fitting (6).
5 Close the air intake fitting (6) with the delivered seal plug (7).
6 Connect the compressed air.
 Fig. 4 Dedusting the filter on page EN-11
7 Open the valve lever (4) on the compressed air connection.
Due to the compressed air, the cleaning nozzle rotates inside the fine filter cartridge. By moving the tube
manually upwards and downwards, the exhaust fume deposits are completely removed from the filter and
the filter is refreshed. The separated dust is collected in the dust collecting drawer.
8 After having switched off the fume extraction system, wait (for approx. 1 minute) until the dust has settled
down in the fume extraction system.
 Fig. 2 Functional Description on page EN-9
9 Remove the knurled nuts (9) from the dust collecting drawer (8).
10Pull the dust collecting drawer (8) carefully out.
11 Put the separated dust from the dust collecting drawer (8) into the delivered dust collecting bag
and close it.
 5.1 Emptying the dust collecting drawer on page EN-10
NOTICE
• The dust collecting drawer (8) must be emptied before and after each dedusting of the filter.
• If the dedusting of the filter has no effect on the suction power, the filter must be replaced.
5.3 Replacing the filter cartridge
After longer operating times, the fine dust penetrates into the filter and the filter becomes clogged. Even a
dedusting of the filter cannot remove this dust. The filter must be replaced by a new one.
Risk of injury due to unexpected start-up
For the entire duration of maintenance, servicing, mounting, dismounting and repair work, the following
instructions must be adhered to:
• Switch off the power source.
• Close off the compressed air supply.
• Pull the mains plug.
EN - 12