Product Description; Designated Use En; Usage Not In Accordance With The Intended Purpose En; Technical Data En - Abicor Binzel FES-2 W3 Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

2 Product description

2 Product description
2.1 Designated use
The fume extraction system FES-200 W3 forms part of the welding system and is intended for manual torch
use. The device corresponds to the welding fume separation class W3. It is designed for the separation of
fumes generated during welding or thermal cutting of steels with alloy constituents such as nickel or chrome
<30% and high-quality steels. Observe the operating, maintenance and servicing conditions.
2.2 Usage not in accordance with the intended purpose
Any use other than that described under "Designated Use" is considered contrary to the designated use.
Unauthorised conversions or power increase modifications are not allowed.
2.3 Technical data
Connection voltage
Drive power
Rated frequency
Filter surface
Connection diameters
Max. vacuum
Min. Unterdruck
Max. air volume flow
Min. air volume
Sound pressure level LpA
Max. air pressure
Weight
Dimensions (LxWxH)
Tab. 1
Ambient temperature
Relative humidity
Ambient conditions during operation
Tab. 2
Storage in a closed environment, ambient temperature
Ambient temperature for transport
Relative humidity
Ambient conditions for transport and storage
Tab. 3
2.4 Abbreviations
FES
Abbreviations
Tab. 4
EN - 4
1
General data
1measured according to the enveloping surface method according to DIN EN ISO 3744
Fume Extraction System
230 V
115 V
1,0 kW
50 Hz
60 Hz
2
0,8 m
50 mm
19.000 Pa
14.500 Pa
200 m³/h
50 m³/h
65 dB(A)
4 bar
24 kg
630 x 210 x 590
+5 °C to + 25 °C
up to 90 % at 20 °C
+5 °C to + 25 °C
- 15 °C to + 40 °C
up to 90 % at 20 °C