Emptying The Dust Collecting Drawer En - Abicor Binzel FES-2 W3 Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

5 Functional Description
5.1 Emptying the dust collecting drawer
Risk of injury due to unexpected start-up
For the entire duration of maintenance, servicing, mounting, dismounting and repair work, the following
instructions must be adhered to:
• Switch off the power source.
• Pull the mains plug.
• Before performing any maintenance and cleaning work, the necessary safety measures must be
• Maintenance and cleaning work on the fume extraction system may only be carried out in areas with
• Always wear your personal protective equipment when performing maintenance and cleaning work.
• The personal protective equipment consists of protective clothing, safety goggles, respirator mask
• Nobody without personal protective equipment may stay near the dust collecting drawer when
1
Remove the knurled nuts from the dust
collecting drawer
Emptying the dust collecting drawer
Fig. 3
Proceed as follows:
 Fig. 2 Functional Description on page EN-9
1 Switch off the fume extraction system by actuating the rotary switch (11).
2 After having switched off the fume extraction system, wait (for approx. 1 minute) until the dust has settled
down in the fume extraction system.
3 Remove the knurled nuts (9) from the dust collecting drawer (8).
4 Pull the dust collecting drawer (8) carefully out.
5 Put the full dust collecting drawer (8) into the delivered dust collecting bag and close it.
6 Turn over the dust collecting drawer (8) so that the dust can fall into the dust collecting bag.
7 Carefully open the dust collecting bag and take the dust collecting drawer out (8).
8 Seal the dust collecting bag tightly.
9 Clean the dust collecting drawer (8) using a damp disposable cloth.
10Clean the dust collecting drawer area (8) using a damp disposable cloth.
11 Slide the empty dust collecting drawer (8) into the fume extraction system.
12 Lock the dust collecting drawer (8) by screwing the knurled nuts (9) onto the fume extraction system.
EN - 10
DANGER
CAUTION
taken.
locally filtered forced ventilation.
class P3, protective gloves and safety shoes.
emptying it.
2
Pull the dust collecting drawer carefully out
FES-200 W3
3
Put the dust collecting drawer in the dust
collecting bag included in the delivery and
close it.

Publicité

Table des Matières
loading

Table des Matières