REMOTE UP/DOWN CONTROL INSTALLATION
All Units
When to use the Remote UP/DOWN Control
The Remote UP/DOWN Control should be used when your cooktop
has a burner that is within 4 inches of the UP/DOWN Button on
the downdraft chimney.
The Remote UP/DOWN Control can be used for convenient UP/
DOWN operation of the downdraft chimney (even when a burner
is more than 4 inches from the UP/DOWN Button of the downdraft
chimney).
How to use the Remote UP/DOWN Control
Do not place the remote control where it will interfere with cook-
ing, where hot pans could be set, or where hot liquids could be
spilled on the control.
The Remote UP/DOWN Control disables the UP/DOWN function
of the UP/DOWN Button on the downdraft chimney.
Installation
1. Using the template at right, lay out the 3-hole pattern on the
counter top. Mark the centers of the three holes to be drilled.
2. Carefully drill the three holes through the counter top. Be careful
not to damage or chip the counter top surface when drilling
the holes.
3. Remove the control from the plastic bag. Line the control up
with the three holes and position the control so it is parallel
with the front of the counter top.
4. Remove the two nylon thumbnuts from the plastic bag and
thread onto the two studs on the control from below the counter
top. Hand tighten only.
WARNING: To reduce the risk of burns or ignition
of clothing by reaching across burners, the remote
control must be mounted at least 4" away from any
cook top burner.
5. Remove the blower, clamp channels, and gearmotor cover from
downdraft (see"Prepare the Downdraft" on page 5). Remove
the large panel to expose the downdraft's wiring.
WIRING
BOX
6. At the lower right hand corner of downdraft, unplug the cable
from the left side of the wiring box.
LOWER
RIGHT
SIDE
OF
DOWNDRAFT
CABINET
FLOOR
.625
.250 DIA.
HOLES
2.000
.438
DIA.
HOLE
1.000
CUT OUT ON DOTTED LINE
CUT OUT
ON DOTTED LINE
WIRING
BOX
7. Remove remote cable from the plastic bag and plug into back
of control from below counter top. Route cable through cabinet
to lower right hand corner of downdraft and through the clear-
ance holes in the side of downdraft and wiring box. Plug cable
into circuit board plug, as shown.
8. Stuff excess cable out of the way, secure the cable so it is
not damaged by items stored in the cabinet, and reassemble
downdraft.