Base plate
Dimensions
Material
Heating
Heating power (-5%/+10%) at nominal voltage
Adjustment and display resolution
Surface temperature
Temperature sensor PT 1000 variation
DIN EN 60751 Kl. A
Temperature variation max. at 100 °C
Heating plate control hysteresis,
no container, center of heating plate at 100 °C
Control hysteresis with temperature sensor
PT 1000
Ü
with ETS-D5
Ü
with ETS-D6
Ü
Adjustable safety circuit
Safety temperature limit (adjustable)
Ü
The control accuracy values given were determined using the following set-up: 500 ml water in 600 ml glass beaker, magnetic stirring bar 40, 600 rpm, 50 °C
Subject to technical changes!
In accordance with IKA
warranty conditions, the warranty period
®
is 24 months. For claims under the warranty please contact your
local dealer. You may also send the machine direct to our factory,
enclosing the delivery invoice and giving reasons for the claim. You
will be liable for freight costs.
mm
W
K
°C
K
K
K
K
°C
°C
°C

Warranty

The warranty does not cover worn out parts, nor does it apply
to faults resulting from improper use, insufficient care or mainte-
nance not carried out in accordance with the instructions in this
operating manual.
Ø135
Al-alloy
600
1
Ambient temperature - 310
≤ ± (0,15 +0,002xITI)
± 1,5
± 5
± 1
± 0,5
± 0,2
50 – 360 (± 10)
25