RESET OF THE DEVICE
Proceed as follows to reset the device:
From any keypad in the system, enter the Installer code in the "Maintenance" menu and delete the
device from the "Delete/Keypads" menu (the device was previously acquired as a keypad, delete the
one with the correct address. For more information, refer to the 1067/xxx control panel installation
manual).
Disconnect the power supply of the device and reconnect it.
Hold down the programming button (PROG) for at least 10 seconds until the green LED lights up
fixed. Now release the button.
The green LED will remain fixed for a few moments and then flash once a second.
The device has performed the reset parameters.
At this point the device is ready to be acquired again.
Led

LED OPERATION

 After a hardware reset, the LED on the board will blink for 10 seconds as for the keypads.
 Board reset in Access Point mode, not acquired by control panel:
 1 blink approximately every 2 seconds.
 Board reset in Access Point mode, acquired:
2 slow blinks with an interval of 8 seconds between sequences.
 Board connected to WiFi/LAN:
a.
Network/IP address acquisition
 2 slow blinks with an interval of 1 seconds between sequences.
b.
Acquired network, searching for Urmet Cloud/certificate
 3 slow blinks with an interval of 1 seconds between sequences.
c.
Network acquired, Urmet Cloud/certificate acquired
 3 slow blinks with an interval of 8 seconds between sequences.
DS1067-107A
Flashes / Description
Reset and
Programming button
The Ethernet connector is to connect