Service; Operation - GOK Caramatic ProTwo Instructions De Montage Et D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

SERVICE

Cylinder replacement during operation
1. Set the changeover device so that GREEN is pointing to the cylinder on the reserve side.
2. Close the cylinder valve of the empty gas cylinder
3. Loosen the connections to the gas cylinder
4. Replace the empty cylinder with a full one and connect the full one.
The gas non-return valve prevents the gas flow from escaping through the free
connection
during cylinder replacement.
5. Open the cylinder valve.
6. Check for leaks.
7. The full cylinder is available as a reserve.

OPERATION

Always turn the changeover device as far as it will go to the operating or reserve side!
No intermediate position.
Type of withdrawal
Operation
The changeover device
GREEN points to the
cylinder on the operating
side.
The visual indicator is at
GREEN "operation".
Reserve - operating side
is empty
The changeover device
GREEN points to the
cylinder on the empty
operating side. The visual
indicator is at RED
"reserve".
Type of withdrawal
Cylinder replacement
during operation
Set the changeover device
so that the rotary knob with
GREEN is pointing to the
cylinder on the reserve
side. The visual indicator
changes from RED
"reserve" to GREEN
"operation". Carry out a
LEAK TESTING.
part no. 02 592 99
Operation
Reserve
Caramatic ProTwo
Caramatic ProTwo
180°
Reserve
Operation
21