Télécharger Imprimer la page

Presto 55050 Notice D'installation page 8

Robinet électronique

Publicité

ENGLISH
1) PRECAUTIONS FOR USE (The product guarantee
depends onthe respect for these rules)
INSTALLATION and START UP
For products delivered with filters, these must be installed
in accordance with the instructions. Before
commissioning any of our valves, it is essential to
carefully drain the pipes that can damage the
mechanisms or water passages. Recommended operating
pressure according to NF EN 816: 1 to 5 bar.
CLEANING
The chrome-plated coating of PRESTO® valves must be
cleaned only with soapy water. Abrasive, acid, alkaline or
ammonia-based household products are prohibited.
2) Ref.
3) Mixer tap
4) Mixer tap without lever
5) Single tap
6) Lithium battery 6V CRP2
7) Transformer 230 VAC/7 VDC IP65
8) Regular auto rince
9) Pop-up waste control
10) PEX hoses G3/8, revolving nut, filter seal
11) Check valve
12) Flow limiter
13) Flow straightener
14) Identification sticker
15) Stop valve MM G3/8
16) Start up
17) This appliance can be used by
children aged from 8 years and above
and persons with reduced physical,
sensory or mental capabilities or lack
of experience and knowledge if they
have been given supervision or
instruction concerning use of the
appliance in a safe way and
understand the hazards involved.
Children shall not play with the
appliance. Cleaning and maintenance
shall be made by qualified staff.
18) For proper operation of the sensor tapware, avoid
installing these product facing a mirror or any other
reflective surfaces. Do not install 2 sensor taps facing one
another.
19) Basket filter seal included
20) Straight stop valve ref. 29860
21) Automatic rinse
22) Flow rate diagram
23) Flow rate
24) Flow straightener
25) Flow limiter
26) Bar
27) Power supply 230 VAC with cable 2 x 0,5mm² min.
Ø 6 to 8,5 mm. Disconnect the supply before any
maintenance on the tap. The transformer is equipped
with thermal protection against overload. In case of
operating, disconnect the power supply for 30 seconds,
fix the problem, then turn it back on.28) Fixing: 2
screws Ø 4.5 max
29)Top
30) Bottom
31)Recommended working pressure: 0,1 Mpa (1 bar) -
0,5 Mpa (5 bar). Maximum working pressure: 0,05 Mpa
(0,5 bar) - 0,8 Mpa (8bar). Protection factor IP54.
32) Mixer tap/adjusting antiscalding stop
33) Preset delivery position
34) To release hot water of 40°C +/- 2°C with equal
pressure, place the limiter as shown below.
35) Hot water \ cold water
36) Mixer tap without lever/adjusting antiscalding stop
37) To get water of 40°C, turn the mixer shaft with a
screwdriver following the arrow untill you get the
desired temperature.
38) Taps with regular rince: automatic rinsing of 30
secondes every 72 hours after the last use (and every
72 hours after) to avoid the water stagnation and to
prevent the growth of legionella.
39) MAINTENANCE
40) Replacing the battery ref. 90941
41) DEAD BATTERY
42) The infrared cell blinks, no use possible.
43) Lithium battery 6V CRP2 ref. 90941
44) Replacing the solenoid valve ref. 90944
45) Solenoid valve
46) Replacing the seal
47) Replacing sensor circuit
48) Battery-powered sensor circuit ref. 90942
49) Mains-powered sensor circuit ref. 90943
ITALIANO
1) PRECAUZIONI D'USO (La garanzia del prodotto è
soggetta alrispetto delle presenti norme)
MONTAGGIO e UTILIZZO
Per quanto riguarda i prodotti consegnati completi di
filtri, questi devono essere tassativamente montati in
conformità a quanto riportato sulle istruzioni. Prima
della messa in funzione dei rubinetti,indipendentemente
dal tipo, è indispensabile spurgare accuratamente le
tubazioni per evitare di danneggiare i meccanismi o i
passaggi dell'acqua. Pressione di servizio
raccomandata, secondo NF EN 816: da 1 a 5 bar.
PULIZIA
Pulire il rivestimento cromato delle rubinetterie
PRESTO® esclusivamente con acqua saponata. Non
utilizzare prodotti detergenti abrasivi, acidi, alcalini o
contenenti ammoniaca.
2) Rif.
3) Miscelatore
4) Miscelatore senza leva
5) Rubinetto monoacqua
6) Pila al litio 6V CRP2

Publicité

loading