Desa SBLP170VT Manuel Du Propriétaire page 5

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

INSTALLATION
Continued
1. Provide propane supply system (see Propane
Supply, page 4).
2. Connect POL fitting on hose/regulator as-
sembly to propane tank(s). Turn POL fitting
counterclockwise into threads on tank. Tighten
firmly using wrench. Tighten regulator with
vent pointing down.
3. Connect hose to inlet connector. Tighten firmly
using a wrench.
IMPORTANT: Extra hose or piping may be
used if needed. Install extra hose or piping
between hose/regulator assembly and propane
tank. You must use the regulator supplied with
heater.
4. Open propane supply valve on propane tank(s)
slowly. Note: If not opened slowly, excess-
flow check valve on propane tank may stop
gas flow. If this happens, close propane supply
valve and open again slowly.
5. Check all connections for leaks.
WARNING: Never use an
open flame to check for a leak.
Apply a mixture of liquid soap
and water to all joints. Bubbles
forming show a leak. Correct all
leaks at once.
6. Close propane supply valve.
Regulator
Supply
Valve
Propane
Tank
Figure 3 - Regulator With Vent Pointing
113959-01B
Hose
POL
Vent
Fitting
(pointing
down)
Down
www.desatech.com
Inlet Connector
Hose
Figure 4 - Hose and Inlet Connector
(Heater may vary from illustration)