28 | MMD 540H Hybrid Multimeter | Electrical Specifications
DC Current
Range
Resolution
40.00mA
10uA
400.0mA
100uA
20A
10mA
Overload Protection: 0.5A / 250V and 20A / 250V Fuse.
Maximum Input: 400mA dc or 400mA ac rms on uA / mA ranges,20A dc or
ac rms on 20A range.
AC Current
Range
Resolution
40.00mA
10uA
400.0mA
100uA
20A
10mA
Overload Protection: 0.5A / 250V and 20A / 250V Fuse.
Frequency Range: 50 to 60 Hz
Maximum Input: 400mA dc or 400mA ac rms on uA / mA ranges, 20A dc or
ac rms on 20A range.
Resistance
Range
Resolution
400.0Ω
0.1Ω
4.000kΩ
1Ω
40.00kΩ
10Ω
400.0kΩ
100Ω
4.000MΩ
1kΩ
40.00MΩ
10kΩ
Capacitance
Range
Resolution
4.000nF
1pF
40.00nF
10pF
400.0nF
0.1nF
4.000uF
1nF
40.00uF
10nF
400.0uF
0.1uF
4.000mF
0.001mF
40.00mF
10.00mF
Robert Bosch LLC
MMD 540H Instruction Manual | Version 1 | December 2010
Accuracy
±1.5% of rdg ±3 dgts
±2.5% of rdg ±5 dgts
Accuracy
±1.8% of rdg ±5 dgts
±3.0% of rdg ±7 dgts
Accuracy
±1.2% of rdg ±4 dgts
±1.0% of rdg ±2 dgts
±1.2% of rdg ±2 dgts
±2.0% of rdg ±3 dgts
Accuracy
±5.0% of rdg±50 dgts
±5.0% of rdg ±7 dgts
±3.0% of rdg ±5 dgts
±10% of rdg ±10 dgts
MMD 540H Hybrid Multimeter | Electrical Specifications | 29
Frequency
Range
Resolution
Sensitivity
4.000kHz
1Hz
>5V RMS
40.00kHz
10Hz
400.0kHz
100Hz
40.00MHz
1kHz
>10V RMS
Duty Cycle
Range
Resolution
0.1%~99.9%
0.1%
Pulse width: >100us, <100ms;
Frequency width: 5Hz – 100kHz
Sensitivity: >5V RMS
Pulse Width
Range
Resolution
1.0~ 20.0ms
0.1ms
Type-K Temperature
Range
Resolution
-30° C~ 1000° C
1° C
-22° F~1832° F
1° F
Sensor: Type K Thermocouple
Diode Test
Test current
Resolution
1.0mA typical
1 mV
Open circuit voltage: 3.0V dc typical
Audible continuity
Audible threshold: Less than35Ω Test current: <1mA dc typical
MMD 540H Instruction Manual | Version 1 | December 2010
Accuracy
±1.5% of rdg ±3 dgts
±2.0% of rdg ±4 dgts
Accuracy
±2% of rdg ±2 dgts
Accuracy
±2% of rdg ±20 dgts
Accuracy
±3% of rdg ±5° C/8° F (Meter
only, probe accuracy not
included)
Accuracy
±5% of rdg ±15 dgts
Robert Bosch LLC