Service
cyclone (see drawing below) and the fi lter can
be removed. When the fi lter bottom is over the
edge, you can turn up the bag and tie with wire
ties. Fold the twisted portion again and lock it
with another cable tie. Ideally, no dust release.
Discard the fi lter according to regulations. Be
sure to check the fi lter seat is clean and the
sealing of the fi lter is intact before the fi lter is
pressed in and the fi lter sits right in the house.
Thereafter, the cyclone top with HEPA fi lter
refi tting. Attention! Fine fi lter may not be used
long after removal from the machine.
With cleaning and maintenance on the machine,
the power cable should be disconnected from the
supply. Fluids should not come into contact with
the motor.
In every motor unit, the fi lter pads (2 pieces, Part
No. 432160) and the air fi lter (1 piece, Part No.
432159) must be replaced at least 6 times a year,
and also when cleaning the machine. These fi lters
are available as a kit, Part No. 432183. Filter
replacement on the DC 3800 H Asbestos model
requires two packs.
DC 3800 H Asbest - 14
Part No 94165-D