OPTIONAL WALL MOUNT THERMOSTAT
DISCONNECT INTEGRAL THERMOSTAT "R", "W", AND "C" LEADS AND ATTACH WALL THERMOSTAT AS SHOWN
W
R
THERMOSTAT
ELECTRONIC
INTEGRAL
ORG
ORG
GRN
RED
RED
The appliance, when installed, must be electrically grounded in accordance
with local codes or, in the absence of local codes, with the National
Electrical Code, ANSI/NFPA 70 or Canadian Electrical Code, CSA C22.1,
if an external electrical source is utilized. This appliance is equipped
with a three-prong [grounding] plug for your protection against shock
hazard and should be plugged directly into a properly grounded
three-prong receptacle. Do not cut or remove the grounding prong
from this plug. For an ungrounded receptacle, an adapter, which has
two prongs and a wire for grounding, can be purchased, plugged into the
ungrounded receptacle and its wire connected to the receptacle mounting
screw. With this wire completing the ground, the appliance cord plug can
be plugged into the adapter and be electrically grounded.
CAUTION: Label all wires prior to disconnection when servicing
controls. Wiring errors can cause improper and dangerous operation.
Verify proper operation after servicing.
Note: For testing flame sensor circuit use a micro-amp meter in series
with sensor. Minimum current should be 1 micro-amp during operation.
Be careful as flame sensor is in the 115VAC circuit. If current is below 1
micro-amp, remove sensor, clean with light sandpaper and retest.
Note: This heater is equipped with a remote bulb electronic thermistor
control located down low at the back of the furnace. Sometimes due to
field locations different air currents may effect the control sensing of the
19563-6-0314
XFMR
GV
6
3
9
8
5
2
7
4
1
BLU
BLU
6
3
5
2
4
1
PUR
PUR
INDUCER
BLOWER
WHT
BLK
CIRCULATING AIR BLOWER
WIRING
ON/OFF
POWER SWITCH
RED LED
STATUS
LIGHT
HOT SURFACE
IGNITOR
IGN
GND
3A FUSE
WHITE
BLACK
ON/OFF
THERMOSTAT
SWITCH
115 VAC
24 VOLT
FIELD INSTALLED
IF ANY OF THE ORIGINAL WIRE AS SUPPLIED WITH THE
APPLIANCE MUST BE REPLACED, IT MUST BE REPLACED
WITH A WIRE OF AT LEAST 105
thermistor. This sensing bulb can be re-located if necessary to provided
for better room air sensing and control.
Replacement of Thermistor with 24 Volt Wall Thermostat
1. If furnace is installed, turn off gas supply and electric supply.
2. Remove casing front.
3. Remove black hose from front nipple on pressure switch.
4. Remove junction box cover (4 screws).
5. Please refer to wiring diagram for removal of the following
wires.
6. Internal Electronic Thermostat/Temperature Control Board
Attention! No 24 volt wall thermostat wires are to be attached
to the internal electronic thermostat.
7. Control Board
A. Remove white wire form screw marked W.
B.
Remove yellow wire from screw marked C.
C.
Remove red wire from screw marked R.
8. Route (2) wires from any 24 volt wall thermostat through the
casing back of furnace to the screws marked W and R on the
control board.
9. Replace junction box cover (4 screws).
10. Replace black hose onto front nipple on pressure switch.
11. Replacement of thermistor with 24 volt wall thermostat is
completed.
GV = GAS VALVE
LS = LIMIT SWITCH
FS = FLAME SENSOR
XFMR = TRANSFORMER
PS = PRESSURE SWITCH
IGN = HOT SURFACE IGNITOR
ROS = ROLLOUT LIMIT SWITCH
CORDSET 115 VAC
BLACK HOT
BLACK NEUTRAL
SMOOTH
RIBBED
INSULATION
INSULATION
CIRCULATING AIR
BLOWER MOTOR
COMBUSTION AIR
INDUCER MOTOR
FLAME SENSOR
PRIMARY
115 VAC
TRANSFORMER
SECONDARY
24 VAC
COMMON
LIMIT
ROLLOUT
PRESSURE
GAS
LIMIT SWITCH
SWITCH
VALVE
° C TEMPERATURE RATING.
R-8191