Lighting Instructions - Empire Heating Systems DV-55E-5 Instructions Pour L'installation Et Manuel Du Propriétaire

Radiateur mural à circulation forcée avec un évent direct
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

FOR YOUR SAFETY READ BEFORE OPERATING
WARNING: If you do not follow these instructions exactly, a fire or explosion
A. This appliance does not have a pilot. It is equipped with an
ignition device which automatically lights the burner.
Do not try to light the burner by hand.
B. BEFORE OPERATING smell all around the appliance area
for gas. Be sure to smell next to the floor because some gas
is heavier than air and will settle on the floor.
WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch;
do not use any phone in your building.
• Immediately call your gas supplier from a neighbor's
phone. Follow the gas supplier's instructions.
• If you cannot reach your gas supplier, call the fire
department.
1.
STOP! Read the safety information above.
2.
Set the thermostat to lowest setting.
3.
Turn off all electric power to the appliance.
4.
This appliance is equipped with an ignition device which
automatically lights the burner. Do not try to light the burner
by hand.
VINYL CAP
GAS CONTROL LEVER SHOWN
VINYL CAP
GAS CONTROL LEVER SHOWN
IN "OFF" POSITION
IN "OFF" POSITION
CONVERTIBLE
CONVERTIBLE
REGULATOR
REGULATOR
TOP VIEW
TOP VIEW
1.
Set the thermostat to lowest setting.
2.
Turn off all electric power to the appliance if service is to be
performed .
3.
Remove control access panel (front panel).
Page 12

LIGHTING INSTRUCTIONS

may result causing property damage, personal injury or loss of life.
OPERATING INSTRUCTIONS
BACK END VIEW
BACK END VIEW
TO TURN OFF GAS TO APPLIANCE
C. Use only your hand to push in or turn the gas control knob.
Never use tools. If the knob will not push in or turn by hand,
don't try to repair it; call a qualified service technician. Force
or attempted repair may result in a fire or explosion.
D. Do not use this appliance if any part has been under water.
Immediately call a qualified service technician to inspect the
appliance and to replace any part of the control system and
any gas control which has been under water.
5.
Remove control access panel (front panel).
6.
Turn gas control knob clockwise
7.
Wait ten (10) minutes to clear out any gas. Then smell for
gas, including near the floor. If you smell gas, STOP! Follow
"B" in the safety information above. If you don't smell gas,
go to the next step.
8.
Turn gas control knob counterclockwise
9.
Replace control access panel (front panel).
10. Turn on all electric power to the appliance.
11. Set thermostat to desired setting.
OFF
12. If the appliance will not operate, follow the instructions "TO
TURN OFF GAS TO APPLIANCE" and call your service
technician or gas supplier.
4.
Turn gas control knob clockwise
force.
5.
Replace control access panel (front panel).
to "OFF."
to "ON".
to "OFF." Do not
19563-6-0314