Empire Heating Systems DV-55E-5 Instructions Pour L'installation Et Manuel Du Propriétaire
Empire Heating Systems DV-55E-5 Instructions Pour L'installation Et Manuel Du Propriétaire

Empire Heating Systems DV-55E-5 Instructions Pour L'installation Et Manuel Du Propriétaire

Radiateur mural à circulation forcée avec un évent direct

Publicité

Les langues disponibles

Les langues disponibles

Liens rapides

Installer: Leave this manual with the appli-
ance.
Consumer: Retain this manual for future refer-
ence.
WARNING: If the information in these instruc-
tions are not followed exactly, a fire or explosion
may result causing property damage, personal
injury or loss of life.
— Do not store or use gasoline or other flamma-
ble vapors and liquids in the vicinity of this or
any other appliance.
— WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch; do not
use any phone in your building.
Immediately call your gas supplier from a
neighbor's phone. Follow the gas suppli-
er's instructions.
If you cannot reach your gas supplier, call
the fire department.
— Installation and service must be performed by
a qualified installer, service agency or the gas
supplier.
INSTALLATION INSTRUCTIONS
OWNER'S MANUAL
Patent # 5.664.555
AND
FAN TYPE
DIRECT VENT
WALL FURNACE
For Installation in
Manufactured (Mobile Home),
Modular or Residential Homes
MODEL
DV-55E-5
This appliance may be installed as an OEM
installation in a manufactured home (USA only)
or mobile home and must be installed in ac-
cordance with the manufacturer's instructions
and the Manufactured Home Construction and
Safety Standard, Title 24 CFR, Part 3280, in the
United States, or the Mobile Home Standard,
CAN/CSA Z240 MH Series, in Canada.
This appliance is only for use with the type(s)
of gas indicated on the rating plate. A conver-
sion kit is supplied with the appliance.
WARNING: If not installed, operated and
maintained in accordance with the manufactur-
er's instructions, this product could expose you
to substances in fuel or from fuel combustion
which can cause death or serious illness.
Page 1

Publicité

Chapitres

Table des Matières
loading

Sommaire des Matières pour Empire Heating Systems DV-55E-5

  • Page 1 DIRECT VENT WALL FURNACE For Installation in Manufactured (Mobile Home), Modular or Residential Homes MODEL DV-55E-5 Patent # 5.664.555 Installer: Leave this manual with the appli- ance. Consumer: Retain this manual for future refer- ence. This appliance may be installed as an OEM...
  • Page 2: Table Des Matières

    TABLE OF CONTENTS SECTION PAGE Important Safety Information ....................... 3 Safety Information for Users of LP Gas ..................4 Requirements for Massachusetts....................5 Introduction ..........................6 Specifications ..........................6 Gas Supply..........................7 Gas Conversion Instructions ....................... 8 Clearances ..........................9 Furnace Installation ........................
  • Page 3: Important Safety Information

    IMPORTANT SAFETY INFORMATION THIS IS A HEATING APPLIANCE DO NOT OPERATE THIS APPLIANCE WITHOUT FRONT PANEL INSTALLED. • Due to high temperatures the appliance should be located • Installation and repair should be done by a QUALIFIED out of traffic and away from furniture and draperies. SERVICE PERSON. The appliance should be inspected before use and at least annually by a qualified service person.
  • Page 4: Safety Information For Users Of Lp Gas

    SAFETY INFORMATION FOR USERS OF LP-GAS Propane (LP-Gas) is a flammable gas which can cause fires and of your household. Someday when there may not be a minute to explosions. In its natural state, propane is odorless and colorless. lose, everyone's safety will depend on knowing exactly what to You may not know all the following safety precautions which can do.
  • Page 5: Requirements For Massachusetts

    REQUIREMENTS FOR MASSACHUSETTS For all side wall horizontally vented gas fueled equipment 3. SIGNAGE. A metal or plastic identification plate shall be installed in every dwelling, building or structure used in permanently mounted to the exterior of the building at a whole or in part for residential purposes, including those minimum height of eight (8) feet above grade directly in owned or operated by the Commonwealth and where the...
  • Page 6: Introduction

    INTRODUCTION Introduction Such equipment shall be located, or protected, so it is not subject Always consult your local Building Department regarding to physical damage by a moving vehicle. regulations, codes or ordinances which apply to the installation of Qualified Installing Agency a direct vent wall furnace. Installation and replacement of gas piping, gas utilization equipment Instructions to Installer or accessories and repair and servicing of equipment shall be...
  • Page 7: Gas Supply

    GAS SUPPLY equate, contact your local authorized installer for installation or Consult the current National Fuel Gas Code, ANSI Z223.1 CAN/ relocation. CGA-B149 (.1 or .2) installation code. Compounds used on threaded joints of gas piping shall be resistant Recommended Gas Pipe Diameter to the action of liquefied petroleum gases.
  • Page 8: Gas Conversion Instructions

    GAS CONVERSION INSTRUCTIONS Warning: Conversion must be done by a qualified service technician. Main burner orifice(s) and new gas conversion label are provided in conversion kit attached to manifold pipe. CONVERSION INSTRUCTIONS FROM (LP) PROPANE GAS TO NATURAL GAS 1. Make sure gas supply to furnace is off prior to conversion and disconnect electrical power to unit. 2.
  • Page 9: Clearances

    CLEARANCES 1. Pick a location on a wall with a clear space of 36" (91.4cm) 50,000 BTU (14.6KW) per hour or more shall be located at least high by 43" (109cm) wide in the room. In selecting a location 12" (305mm) from any opening through which flue gases could for installation, it is necessary to provide adequate accessibility enter a building.
  • Page 10 2" (51mm) TO 13" (330mm) 4" (102mm) CASING WALL 2" (51mm) TO 32" (813mm) WALL MOUNTING BRACKET BACK #10 X 1" #10 X 1/2" WALL BRACKET #10 X 1/2" Figure 6 Figure 4 Installing Wall Bracket (Figures 5 and 6) After finding a location for the furnace, gas supply and vent, the wall bracket must be positioned and installed.
  • Page 11 FURNACE INSTALLATION (continued) Vent Terminal (Figure 9) Venting (Figures 7 and 8) Place the 6 3/8" x 6 3/8" (162mm x 162mm) black foam, wall plate This unit is vented directly out the back using the concentric vent gasket within the mounting plate. The 4 3/4" (121mm) diameter tube assembly provided.
  • Page 12: Lighting Instructions

    LIGHTING INSTRUCTIONS FOR YOUR SAFETY READ BEFORE OPERATING WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. A. This appliance does not have a pilot. It is equipped with an C.
  • Page 13: Wiring

    WIRING GV = GAS VALVE LS = LIMIT SWITCH FS = FLAME SENSOR XFMR = TRANSFORMER PS = PRESSURE SWITCH IGN = HOT SURFACE IGNITOR ROS = ROLLOUT LIMIT SWITCH OPTIONAL WALL MOUNT THERMOSTAT DISCONNECT INTEGRAL THERMOSTAT "R", "W", AND "C" LEADS AND ATTACH WALL THERMOSTAT AS SHOWN CORDSET 115 VAC XFMR BLACK HOT...
  • Page 14: Maintenance

    MAINTENANCE Removing Gas Valve Proper Main Burner Flame 1. Remove front grill assembly. The proper main burner flame will be a blue primary (inner) flame 2. Disconnect manifold union assembly at gas valve. with a larger, lighter blue secondary (outer) blue flame. 3.
  • Page 15: Operation And Troubleshooting

    OPERATION AND TROUBLESHOOTING Your new furnace should provide many years of trouble free The hot surface ignitor is energized and after a 17 second warm- performance, however, a yearly inspection of the burners , flue up, the gas valve circuit is energized, opening the gas valve and passageways and the outlet vent assembly should be done.
  • Page 16 FURNACE CONTROL BOARD DIAGNOSTICS FAULT SEQUENCE CODE — TROUBLE SHOOTING GUIDE # of Blinks Fault Condition Fault Correction Steady On Control OK 1 Flash Temperature limit switch is open -Check Circulating Air Blower Inlet or Grill Outlet for Blockage, Inducer Blower/Circulating Air Blower Run to Cool Heat Exchanger and Limit -Check for Flame Roll Out Condition Causing Roll Out Limit Switch on Burner Box to Open...
  • Page 17: How To Order Repair Parts

    HOW TO ORDER REPAIR PARTS Parts can be ordered only through your service person or dealer. For best results, the service person or dealer should order parts through the distributor. Parts can be shipped directly to the service person/dealer. All parts listed in the Parts List have a Part Number. When ordering parts, first obtain the Model Number from the name plate on your equipment.
  • Page 18: Parts View

    PARTS VIEW Page 18 19563-6-0314...
  • Page 19: Master Parts Distributor List

    MASTER PARTS DISTRIBUTOR LIST To Order Parts Under Warranty, please contact your local Empire dealer. See the dealer locator at www.empirecomfort.com. To provide warranty service, your dealer will need your name and address, purchase date and serial number, and the nature of the problem with the unit.
  • Page 20: Warranty

    WARRANTY Empire Comfort Systems Inc. warranties this space heating product to be free from defects at the time of purchase and for the periods specified below. Space heating products must be installed by a qualified technician and must be maintained and operated safely, in accordance with the instructions in the owner’s manual.
  • Page 21: Radiateur Mural Àcirculation Forcée Avec Un Évent Direct

    AVEC UN ÉVENT DIRECT POUR L’INSTALLATION DANS DES MAISONS PRÉ-FABRIQUÉES (MAISON MOBILE), MODULAIRES OU RÉSIDENTIELLES MODÈLES DV-55E-5 Brevet # 5.664.555 Installateur: Laissez cette notice avec l’appareil. Consommateur: Conservez cette notice pour consultation ultériure. AVERTISSEMENT: Assurez vous de bien suivre les instructions données dans cette notice pour réduire...
  • Page 22 LA TABLE DES MATIÈRES TABLE OF CONTENTS SECTION PAGE Information Importante de Sécurité ......................3 Information de Sécurité pour les Utilisateurs de Propane ................. 4 Introduction ..............................5 Spécifications ............................. 5 Alimentation en Gaz ..........................6 Les Instructions Pour La Conversion des Gaz ................... 7 Espaces Libres ............................
  • Page 23: Information Importante De Sécurité

    INFORMATION IMPORTANTE DE SÉCURITÉ CECI EST UN APPAREIL DE CHAUFFAGE NE PAS FAIRE FONCTIONNER CET APPAREIL SANS QUE LE PANNEAU DU DEVANT SOIT INSTALLÉ. • A cause des hautes températures, cet appareil doit être situé • L'installation et la réparation doivent être faites par une dans un endroit non achalandé...
  • Page 24: Information De Sécurité Pour Les Utilisateurs De Propane

    INFORMATION DE SÉCURITÉ POUR LES UTILISATEURS DE PROPANE Le propane est un gaz inflammable qui peut causer des feux et bres de votre famille. Un jour, lorsqu'il n'y aura pas une minute des explosions. Dans son état naturel, le propane est inodore et à...
  • Page 25: Introduction

    INTRODUCTION Introduction appareils pour allumer les brûleurs doivent être situés à au moins Toujours consulter le département de construction de votre région 18” (457mm) au dessus du plancher. en ce qui regarde les règlements, les codes ou les ordonnances qui Tous ces équipements doivent être situés ou protégés de façon à...
  • Page 26: Alimentation En Gaz

    ALIMENTATION EN GAZ Installation d’un Nouveau Robinet Principal pour le Gaz Consulter le Code d’Installation en Cours du National Fuel Gas Chaque appareil doit avoir son propre robinet manuel de gaz. Code, ANSI Z223.1 CAN/CGA-B149 (.1 ou .2). Dans l'État de Massachusetts, le robinet de gaz doit être une Le Diamètre recommandé...
  • Page 27: Les Instructions Pour La Conversion Des Gaz

    LES INSTRUCTIONS POUR LA CONVERSION DES GAZ Attention: Conversion doit être faite par un technicien d'entretien qualifié. Les orifices du brûleur principal et la nouvelle étiquette pour le changement des gaz sont fournis dans l'ensemble de conversion qui est attaché au tuyau de gaz. LES INSTRUCTIONS POUR LA CONVERSION DU GAZ PROPANE (PL) AU GAZ NATUREL 1.
  • Page 28: Installation Du Radiateur

    CLEARANCES 1. Choisissez un endroit sur un mur qui aura un espace libre de 36” sance d'entrée de 50,000 Btu (14.6KW) par heure ou moins, doit (91.4cm) de haut par 43” (109cm) de large. En choisissant un être situé à au moins 12” (305mm) d'une ouverture dont les gaz emplacement, il est nécessaire de fournir l'espace libre adéquat d'échappement peuvent entrer dans le bâtiment.
  • Page 29 2” (51mm) À 13” (330mm) POUR L'ENSEMBLE D'ÉVENT STANDARD 2” (51mm) À 32” (813mm) AVEC LES BLINDAGE DU DESSUS ACCESSOIRES DE L'ENSEMBLE ALLONGÉ SUPPORT MURAL COUDE D'ÉVACUATION 4” (102mm) AVEC COLLIER ¾” (19mm) MINIMUM DE LA PLAQUE MURALE PAROI ARRIÉRE DE SERRAGE SUPPORT DE MONTAGE ALLANT VERS...
  • Page 30: Installation Du Radiateur (Suite)

    INSTALLATION DU RADIATEUR (SUITE) Les vis sont fournies dans le paquet de quincaillerie. Insérez le Évacuation (Figures 7 and 8) filtre à air dans la paroi du dessus. L'évacuation des gaz de cet appareil est faite directement à l'arrière en utilisant un ensemble de tuyau d'évent concentrique, fourni avec Attention: Si la paroi du côté...
  • Page 31: Instructions D'allumage

    INSTRUCTIONS D’ALLUMAGE POUR VOTRE SÉCURITÉ, LIRE AVANT D'ALLUMER AVERTISSEMENT: SI VOUS NE SUIVEZ PAS EXACTEMENT CES INSTRUCTIONS, UN FEU OU UNE EXPLOSION PEUT SE PRODUIRE CAUSANT DES DOMMAGES À LA PROPRIÉTÉ, DES BLESSURES CORPORELLES OU LA MORT. du fournisseur de gaz. A.
  • Page 32 WIRING SCHÉMA DE CÂBLAGE AVERTISSEMENT: DÉBRANCHER L'ALIMENTATION ÉLECTRIQUE AVANT TOUTE INTERVENTION GV = ROBINET DE GAZ LS = CONTACT FIN DE COURSE FS = CAPTEUR DE FLAMME XFMR = TRANSFORMATEUR THERMOSTAT MURAL EN OPTION PS = MANOCONTACT IGN = ALLUMEUR SURFACE CHAUDE DÉBRANCHER LES FILS “R”, “W”...
  • Page 33: Maintenance

    MAINTENANCE 1. Enlever l'assemblage du grillage avant. Aspect Convenable de la Flamme du Brûleur Principal 2. De la valve de gaz, débrancher le raccord du tuyau de gaz. La flamme convenable pour le brûleur principal consistera 3. De la valve de gaz, enlever (2) deux fils de 24 volt. Identifier d'une flamme (intérieure) primaire bleue avec une flamme les fils avant de les débrancher de la valve de gaz.
  • Page 34: Fonctionnement Et Détection Des Défectuosités

    FONCTIONNEMENT ET DÉTECTION DES DÉFECTUOSITÉS Votre nouveau radiateur vous apportera plusieurs années de circuit d'induction pour la soufflerie est alimenté et l'inducteur performance sans trouble, par contre, une inspection annuelle des de la soufflerie se met en marche pour 15 secondes purgeant tout brûleurs, des tuyaux d'évacuation et l'ensemble d'évent extérieur gaz et fermant l'interrupteur de pression.
  • Page 35 DIAGNOSTIC DU CIRCUIT DE COMMANDE DE CHAUDIÈRE CODE D’ERREUR SÉQUENTIEL — GUIDE DE DÉPANNAGE Clignotements État d’erreur Correction de l’erreur Allumé Commande OK en continu 1 clignotement Le rupteur thermique est ouvert -Vérifier l’absence d’obstruction de l’admission ou la grille de refoulement de soufflante d’air de chauffage, conduite de soufflante d’induction/air de chauffage vers échangeur et rupteur -Voir s’il y a un retour de flamme causant l’ouverture du limiteur de...
  • Page 36: Façon De Commander Les Pièces De Réparation

    FAÇON DE COMMANDER LES PIÈCES DE RÉPARATION Les pièces peuvent être commandées seulement par l'entremise du technicien d'entretien ou du vendeur. Pour de meilleurs résultats, le technicien d'entretien ou le vendeur devrait commander les pièces chez le distributeur. Les pièces peuvent être expédiées directement au technicien d'entretien ou au vendeur.
  • Page 37: Vue Des Pièces

    VUE DES PIÈCES 19563-6-0314 Page 37...
  • Page 38: Notes De Service

    NOTES DE SERVICE Date Nom du distributeur Nom du technicien de service Entretien effectué/notes...
  • Page 39: Liste Des Distributeurs De Pièces Principaux

    LISTE DES DISTRIBUTEURS DE PIÈCES PRINCIPAUX Pour commander des pièces sous garantie, adressez-vous au revendeur Empire local. Veuillez voir le concessionnaire au www.empirecomfort.com. Pour assurer un service sous garantie, le revendeur doit connaître votre nom, votre adresse, la date d’achat et le numéro de série du produit, ainsi qui la nature du problème. Pour commander des pièces après expiration de la période de garantie, veuillez communiquer avec votre revendeur ou avec l’un des distributeurs de pièces principaux indiqués ci-dessous.
  • Page 40: Garantie

    GARANTIE Empire Comfort Systems Inc. garantit que ce produit de chauffage individuel est exempt de défauts au moment de son achat et pen- dant les périodes indiquées ci-dessous. Les produits de chauffage individuel doivent être installés par un technicien qualifié et doivent être entretenus et utilisés de façon sécuritaire, en conformité...

Ce manuel est également adapté pour:

4277

Table des Matières