Empire Heating Systems DVC35IPXLP-1 Instructions Pour L'installation Et Manuel Du Propriétaire

Empire Heating Systems DVC35IPXLP-1 Instructions Pour L'installation Et Manuel Du Propriétaire

Radiateur mural à circulation forcée avec un évent direct
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Liens rapides

WARNING
FIRE OR EXPLOSION HAZARD
If the information in these instructions is
not followed exactly, a fire or explosion may
result causing property damage, personal
injury or loss of life.
— Do not store or use gasoline or other
flammable vapors and liquids in the
vicinity of this or any other appliance.
— WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch;
do not use any phone in your building.
Leave the building immediately.
Immediately call your gas supplier
from a neighbor's phone. Follow
the gas supplier's instructions.
If you cannot reach your gas
supplier, call the fire department.
— Installation and service must be
performed by a qualified installer,
service agency or the gas supplier.
INSTALLATION INSTRUCTIONS
AND OWNER'S MANUAL
FAN TYPE
DIRECT - VENT WALL
FURNACE MODEL:
DVC35IPXLP-1
DVC35IPXNAT-1
INSTALLER:
Leave this manual with the appliance.
CONSUMER:
Retain this manual for future reference.
WARNING
If not installed, operated and maintained in
accordance with the manufacturer's instructions,
this product could expose you to substances in
fuel or from fuel combustion which can cause
death or serious illness.
This appliance may be installed in an aftermarket,
permanently located manufactured home (USA
only) or mobile home, where not prohibited by
state or local codes.
This appliance is only for use with the type
of gas indicated on the rating plate.
appliance is not convertible for use with other
gases, unless a certified kit is used.
DVC35SPPXLP-1
DVC35SPPXNAT-1
This
Page 1

Publicité

Chapitres

Table des Matières
loading

Sommaire des Matières pour Empire Heating Systems DVC35IPXLP-1

  • Page 1 INSTALLATION INSTRUCTIONS AND OWNER’S MANUAL FAN TYPE DIRECT - VENT WALL FURNACE MODEL: DVC35IPXLP-1 DVC35SPPXLP-1 DVC35IPXNAT-1 DVC35SPPXNAT-1 INSTALLER: Leave this manual with the appliance. CONSUMER: Retain this manual for future reference. WARNING WARNING If not installed, operated and maintained in...
  • Page 2: Table Des Matières

    TABLE OF CONTENTS SECTION PAGE Important Safety Information ......................3 Safety Information for Users of Propane Gas ................4 Requirements for Massachusetts ....................5 Introduction..........................6-7 Specifications ..........................7 Gas Supply ..........................8-9 Clearances ............................ 9 Installation Instructions ......................10-12 DVC-35SPP Standing Pilot Lighting Instructions ................
  • Page 3: Important Safety Information

    IMPORTANT SAFETY INFORMATION THIS IS A HEATING APPLIANCE DO NOT OPERATE THIS APPLIANCE WITHOUT FRONT PANEL INSTALLED. • Due to high temperatures, the appliance should be • DO NOT put anything around the furnace that will located out of traffic and away from furniture and obstruct the flow of combustion and ventilation air.
  • Page 4: Safety Information For Users Of Propane Gas

    SAFETY INFORMATION FOR USERS OF PROPANE GAS Propane is a flammable gas which can cause fires and explo- SOME POINTS TO REMEMBER sions. In its natural state, propane is odorless and colorless. • Learn to recognize the odor of Propane Gas. Your local Propane You may not know all the following safety precautions which Gas Dealer can give you a “Scratch and Sniff”...
  • Page 5: Requirements For Massachusetts

    REQUIREMENTS FOR MASSACHUSETTS For all side wall horizontally vented gas fueled equipment installed SIGNAGE. A metal or plastic identification plate shall be per- in every dwelling, building or structure used in whole or in part for manently mounted to the exterior of the building at a minimum residential purposes, including those owned or operated by the height of eight (8) feet above grade directly in line with the Commonwealth and where the side wall exhaust vent termination...
  • Page 6: Introduction

    INTRODUCTION Introduction Qualified Installing Agency Always consult your local Building Department regarding regula- Installation and replacement of gas piping, gas utilization tions, codes or ordinances which apply to the installation of a di- equipment or accessories and repair and servicing of equipment rect vent wall furnace.
  • Page 7: Specifications

    Description *DV-822 Vinyl Siding Vent Kit VSK2 Vinyl Siding Vent Kit CONVERSION KITS Model Number Description Used On DV1350 Propane to Natural DVC35IPXLP-1 DV1348 Natural to Propane DVC35IPXNAT-1 DV1346 Propane to Natural DVC35SPPXLP-1 DV1344 Natural to Propane DVC35SPPXNAT-1 37402-5-0620 Page 7...
  • Page 8: Gas Supply

    GAS SUPPLY Locating Gas Supply Installing a New Main Gas Shut-Off The gas line can enter the unit either through the floor or outside Each appliance should have its own manual gas shut-off. wall. The gas line opening should be made at this time. Location A manual main gas shut-off should be located in the vicinity of of the opening will be determined by the position of floor joists and the unit.
  • Page 9: Clearances

    GAS SUPPLY (CONT’D) Checking Manifold Pressure TOP VIEW OF VALVE Both Propane and Natural Gas valves have a built-in pressure reg- ulator in the gas valve. Natural Gas models will have a manifold PRESSURE REGULATOR VENT pressure of approximately 4.0” w.c. (.996kPa) at the valve outlet with the inlet pressure to the valve from a minimum of 5.0”...
  • Page 10: Installation Instructions

    INSTALLATION INSTRUCTIONS Locating Wall Opening Place the register over the 6 3/4” (171mm) square opening with The furnace is to be located on an outside wall. Locate wall studs the louvers positioned for the desired discharge direction and so that wall opening will be located between wall studs. The fur- mark the mounting holes using the register as a template.
  • Page 11 INSTALLATION INSTRUCTIONS (CONT’D) Locating Electric Supply Attach 4” (102mm) diameter flue outlet tube onto flue outlet A 7/8” (22mm) diameter knockout is provided at the bottom of the collar on combustion chamber. Be sure 4” (102mm) diameter left and right side panels. A three-prong (grounding) plug assembly flue outlet tube is placed as far as possible onto the collar of is located within the control compartment (bottom) of the furnace.
  • Page 12 INSTALLATION INSTRUCTIONS (CONT’D) Reassembly and Resealing Vent-Air Intake System Vinyl siding kit, DV-822, is available from Empire Comfort Sys- When vent-air intake system is removed for servicing the furnace, tems, Inc. The depth is 3” (76mm), which enables the vent cap to the following steps will assure proper reassembly and resealing of be extended away from siding or projections.
  • Page 13: Dvc-35Spp Standing Pilot Lighting Instructions

    DVC-35SPP STANDING PILOT LIGHTING INSTRUCTIONS FOR YOUR SAFETY READ BEFORE LIGHTING WARNING If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. A. This appliance has a pilot which must be lighted by hand. •...
  • Page 14: Dvc-35Ip Intermittent Pilot Lighting Instructions

    DVC-35IP INTERMITTENT PILOT LIGHTING INSTRUCTIONS FOR YOUR SAFETY READ BEFORE LIGHTING WARNING If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. A. This appliance is equipped with an ignition device which C.
  • Page 15: Pilot Flame Characteristics

    PILOT FLAME CHARACTERISTICS The correct pilot flame (Figure 11) will be blue, extending past THERMOCOUPLE the thermocouple. The flame will surround the thermocouple just below the tip. Natural Gas pilots require adjusting when the inlet gas pressure is above 5” w.c. (1.245kPa). Remove the pilot cover screw on the BURNER control valve (Figure 3), and turn the adjustment screw clockwise to reduce flame.
  • Page 16: Main Burner Flame Characteristics

    MAIN BURNER FLAME CHARACTERISTICS The correct flame will be a short, blue inner flame with a much larger, light blue, outer flame. The burner does not have a primary air adjustment. The flame will be correct if the factory-set pressure and orifice opening are used.
  • Page 17: Service And Maintenance Suggestions

    SERVICE AND MAINTENANCE SUGGESTIONS GENERAL: All furnaces have been fire-tested to check for proper If Pilot Does Not Remain On After Releasing Knob: operation. This includes, main burner flame, pilot flame, fan op- Follow instructions and hold button down longer and harder. eration, fan control, limit control and automatic valve operation.
  • Page 18: Dvc-35Ip Intermittent Pilot Sequence Of Operation

    DVC-35IP INTERMITTENT PILOT SEQUENCE OF OPERATION Apply 24 VAC START To Appliance Call for Heat 5 Minute Retry Delay Pilot Valve Ignition OFF Flame Signal Wait for Flame Signal to Detected Disappear System Check Internal Check Trial for Pilot Valve Opens Ignition Ignitor Powered Pilot Light and Flame is...
  • Page 19: Dvc-35Ip Intermittent Pilot System Troubleshooting Sequence

    DVC-35IP INTERMITTENT PILOT SYSTEM TROUBLESHOOTING SEQUENCE START IP SYSTEM TROUBLESHOOTING SEQUENCE Turn OFF Gas Supply INSET A End View Disconnect System Control SmartValve System Troubleshooting Sequence End View of Control INSET A 24 Volt Harness Harness of Control Note: Before Troubleshooting, Become Familiar Thermostat Connector Harness...
  • Page 20: Parts List

    PARTS LIST PLEASE NOTE: When ordering parts, it is very important that part number and description of part coincide. INDEX PART INDEX PART DESCRIPTION DESCRIPTION DV1213 TOP PLATE OBSERVATION HOLE COVER WITH DV781 MICA R3165 DOOR CLIP (2 REQUIRED) M155 GASKET - OBS HOLE 39476 CASING SIDE - RIGHT...
  • Page 21: Parts View

    PARTS VIEW 37402-5-0620 Page 21...
  • Page 22: Master Parts Distributor List

    MASTER PARTS DISTRIBUTOR LIST To Order Parts Under Warranty, please contact your local Empire dealer. See the dealer locator at www.empirecomfort. com. To provide warranty service, your dealer will need your name and address, purchase date and serial number, and the nature of the problem with the unit.
  • Page 23: Warranty

    WARRANTY Empire Comfort Systems Inc. warranties this space heating product to be free from defects at the time of purchase and for the periods specified below. Space heating products must be installed by a qualified technician and must be maintained and operated safely, in accordance with the instructions in the owner’s manual.
  • Page 24 Empire Comfort Systems Inc. Belleville, IL If you have a general question about our products, please e-mail us at info@empirecomfort.com. If you have a service or repair question, please contact your dealer. www.empirecomfort.com Page 24 37402-5-0620...
  • Page 25 INSTRUCTIONS POUR L’INSTALLATION ET MANUEL DU PROPRIÉTAIRE RADIATEUR MURAL À CIRCULATION FORCÉE AVEC UN ÉVENT DIRECT MODÈLES : DVC35IPXLP-1 DVC35SPPXLP-1 DVC35IPXNAT-1 DVC35SPPXNAT-1 INSTALLATEUR : Laissez cette notice avec l’appareil. CONSOMMATEUR : Conservez cette notice pour consultation ultériure. AVERTISSEMENT AVERTISSEMENT RISQUE D’INCENDIE OU D’EXPLOSION Si l’installation, l’usage et l’entretien de ce produit...
  • Page 26 TABLE DES MATIÈRES SECTION PAGE Importante Information de Sécurité ..................3 Information de Sécurité pour les Utilisateurs de Propane ............4 Introduction ..........................5 Spécifications..........................5 Alimentation en Gaz .......................6 Espaces Libres ........................7 Instructions pour L'Installations ..................8-10 Instructions d'Allumage de la Veilleuse Fixe pour le Modèle DVC-35SPP .....11 Instructions d'Allumage de la Veilleuse Intermittente pour le Modèle DVC-35IP ....12 Aspect Convenable de la Flamme de la Veilleuse ..............13 Aspect Convenable de la Flamme du Brûleur Principal ............14...
  • Page 27: Importante Information De Sécurité

    IMPORTANTE INFORMATION DE SÉCURITÉ CECI EST UN APPAREIL DE CHAUFFAGE NE PAS FAIRE FONCTIONNER CET APPAREIL SANS QUE LA PAROI FRONTALE SOIT INSTALLÉE. • A cause des hautes températures, cet appareil doit être situé • Ne rien mettre autour du radiateur qui pourrait obstruer le dans un endroit non achalandé...
  • Page 28: Information De Sécurité Pour Les Utilisateurs De Propane

    INFORMATION DE SÉCURITÉ POUR LES UTILISATEURS DE PROPANE Le Propane est un gaz inflammable qui peut causer des feux et des ex- point par point avec les membres de votre famille. Un jour, lorsqu’il n’y plosions. Dans son état naturel, le propane est inodore et sans couleur. aura pas une minute à perdre, la sécurité de chacun dépendra de votre Peut-être que vous ne connaissez pas toutes les précautions décrites ci- savoir-faire.
  • Page 29: Introduction

    INTRODUCTION Introduction Installation dans les Garages Residentiels Toujours consulter le département de construction de votre région en ce Tous les équipements dans les garages résidentiels employant du gaz, qui regarde les règlements, les codes ou les ordonnances qui s’appliquent doivent être installés de façon à ce que les brûleurs et les appareils pour à...
  • Page 30: Spécifications

    L’assemblage dévent pour le revêtement en vinyle VSL2 L’assemblage dévent pour le revêtement en vinyle KITS DE CONVERSION Numéro de modèle La description Utilisé sur DV1350 Propane to Naturel DVC35IPXLP-1 DV1348 Naturel to Propane DVC35IPXNAT-1 DV1346 Propane to Naturel DVC35SPPXLP-1 DV1344 Naturel to Propane...
  • Page 31: Alimentation En Gaz

    ALIMENTATION EN GAZ Emplacement de l'Alimentation de Gaz Un robinet manuel principal doit être situé près de l’appareil. S’il n’y en La ligne de gaz peut entrer dans l’appareil soit en venant du plancher ou a pas ou si la grosseur ou l’emplacement est inadéquat, contacter votre du mur extérieur.
  • Page 32: Espaces Libres

    ALIMENTATION EN GAZ (SUITE) Vérifier les Pressions de Gaz VALVE VUE DE DESSUS Un régulateur de pression est incorporé dans la valve de Gaz Propane et RÉGULATEUR DE ÉVENT PRESSION CONNECTEUR TH/TR celle de Gaz Naturel. Les modèles pour le Gaz Naturel auront des pres- PRISE POUR SORTIE DE sions de gaz approximativement de 4"...
  • Page 33: Instructions Pour L'installations

    INSTRUCTIONS POUR L'INSTALLATION Emmplacement de l’Ouverture dans le Mur par dessus le trémie extérieur. Passer le trémie extérieur à travers le Le radiateur doit être situé sur un mur extérieur. Trouver les montants mur et attacher la plaque murale de côté au mur du côté du radiateur du mur, ainsi l’ouverture dans le mur sera entre les montants du mur.
  • Page 34 tion. Soyez certain que le tuyau d’échappement de 4" (102mm) de Emplacement de l’Alimentation Electrique diamètre est placé aussi loin que possible sur le collet de la sortie Sur le bas des panneaux des côtés gauche et droit, il y a une entrée défon- d’échappement.
  • Page 35 INSTRUCTIONS POUR L'INSTALLATION (SUITE) Appliquer du ciment pour radiateur ou du silicone RTV au collet de Calfeutrer la sortie d’échappement de 4" (102mm) de diamètre et sur le collet de 4" (102mm) de diamètre du capuchon d’évent. Attacher le tuyau Plaque extérieure de montage de sortie d’échappement de 4"...
  • Page 36: Instructions D'allumage De La Veilleuse Fixe Pour Le Modèle Dvc-35Spp

    INSTRUCTIONS D'ALLUMAGE DE LA VEILLEUSE FIXE POUR LE MODÈLE DVC-35SPP POUR VOTRE SÉCURITÉ LIRE AVANT D’ALLUMER AVERTISSEMENT Si vous ne suivez pas exactement ces instructions, un feu ou une explosion peut se produire causant des dommages à la propriété, des blessures corporelles ou la mort. A.
  • Page 37: Instructions D'allumage De La Veilleuse Intermittente Pour Le Modèle Dvc-35Ip

    INSTRUCTIONS D'ALLUMAGE DE LA VEILLEUSE INTERMITTENTE POUR LE MODÈLE DVC-35IP POUR VOTRE SÉCURITÉ LIRE AVANT D’ALLUMER AVERTISSEMENT Si vous ne suivez pas exactement ces instructions, un feu ou une explosion peut se produire causant des dommages à la propriété, des blessures corporelles ou la mort. A.
  • Page 38: Aspect Convenable De La Flamme De La Veilleuse

    ASPECT CONVENABLE DE LA FLAMME DE LA VEILLEUSE La flamme de la veilleuse (Figure 11) sera bleue et s’allongera plus loin THERMOCOUPLE que le thermocouple. La flamme entourera le thermocouple juste en- dessous de la pointe. Les veilleuses au Gaz Naturel exigent un ajustement lorsque la pression d’entrée de gaz est supérieure à 5.0" w.c. (1.25kPa). Enlever la vis du BRÛLEUR couvercle de la veilleuse sur la soupape de contrôle (Figure 3) et tourner la vis d’ajustement dans le sens des aiguilles d’une montre pour réduire...
  • Page 39: Aspect Convenable De La Flamme Du Brûleur Principal

    ASPECT CONVENABLE DE LA FLAMME DU BRÛLEUR PRINCIPAL La flamme convenable aura une petite flamme bleue intérieure avec une flamme extérieure bleue pâle beaucoup plus grande. Il n’y a pas d’ajustement d’air primaire pour le brûleur. La flamme se corrigera si la pression pré- ajustée à l’usine et les ouvertures sont utilisées. Après que le radiateur ait fonctionné, il se peut que les ouvertures du brûleur soient bloquées par des TUYAU DE matières étrangères venant de l’air de combustion. Donc un nettoyage du L'ÉCHANGEUR FLAMME brûleur peut être exigé pour obtenir une flamme convenable.
  • Page 40: Suggestions Pour Le Service Et L'entretien

    SUGGESTIONS POUR LE SERVICE ET L’ENTRETIEN Général: Tous les radiateurs ont reçu un test d’allumage pour vérifier La veilleuse s’éteint lors d’une opération normale. le bon fonctionnement. Ceci inclus la flamme du brûleur principal, la 1. Vérifier le tuyau d’entrée d’air pour qu’il soit bien ajusté aux deux flamme de la veilleuse, le fonctionnement du ventilateur, le contrôle du extrémités [tuyau 6" (152mm) diamètre]. ventilateur, le contrôle de fin de course et le fonctionnement de la valve 2. Vérifier que la porte du brûleur et le couvercle de l’ouverture de la automatique.
  • Page 41: Séquence De Fonctionnement De La Veilleuse Intermittente Pour Le Modèle Dvc-35Ip

    SÉQUENCE DE FONCTIONNEMENT DE LA VEILLEUSE INTERMITTENTE POUR LE MODÈLE DVC-35IP Appliquer 24 VAC à DÉPART l'appareil Les appels à la chaleur Délai de 5 minutes, Essai de Nouveau - Allumage de la Soupape Signal de la Flamme est de la Veilleuse OFF Détecté...
  • Page 42: Guide De Détection Des Défectuosités Du Système De La Veilleuse Intermittente Pour Le Modèle Dvc-35Ip

    GUIDE DE DÉTECTION DES DÉFECTUOSITÉS DU SYSTÈME DE LA VEILLEUSE INTERMITTENTE POUR LE MODÈLE DVC-35IP Départ - Fermer l'Alimentation de Gaz - Débrancher le Harnais du GRAPHIQUE A Vue de l'extrémité Système de Contrôle Guide de détection des défectuosités pour le système des connecteurs de 24 Volt “SmartValve”...
  • Page 43: Liste Des Distributeurs De Pièces Principaux

    LISTE DES DISTRIBUTEURS DE PIÈCES PRINCIPAUX Pour commander des pièces sous garantie, adressez-vous au revendeur Empire local. Veuillez voir le concessionnaire au www.empirecomfort.com. Pour assurer un service sous garantie, le revendeur doit connaître votre nom, votre adresse, la date d’achat et le numéro de série du produit, ainsi qui la nature du problème. Pour commander des pièces après expiration de la période de garantie, veuillez communiquer avec votre revendeur ou avec l’un des distributeurs de pièces principaux indiqués ci-dessous.
  • Page 44: Listes Des Pièces

    LISTE DES PIÈCES S’IL VOUS PLAÎT NOTER: Lorsque vous commandez les pièces, il est très important que le numéro de la pièce et la description coïncident. Numéro Numéro Numéro Numéro Description Description d’index de la pièce d’index de la pièce FF-160 Support pour le piezo (SPP seulement) DV-1213...
  • Page 45: Vue Des Pièces

    VUE DES PIÈCES VEILLEUSE ET SUPPORT POUR LES MODÉLES SPP 37402-5-0620 Page 21...
  • Page 46: Garantie

    GARANTIE Empire Comfort Systems Inc. garantit que ce produit de chauffage individuel est exempt de défauts au moment de son achat et pen- dant les périodes indiquées ci-dessous. Les produits de chauffage individuel doivent être installés par un technicien qualifié et doivent être entretenus et utilisés de façon sécuritaire, en conformité...
  • Page 47: Maintenance Historique De L'appareil

    MAINTENANCE HISTORIQUE DE L’APPAREIL Date Nom du distributeur Nom du technicien de service Entretien effectué/notes 37402-5-0620 Page 23...
  • Page 48 Empire Comfort Systems Inc. Belleville, IL Pour toute question générale concernant nos produits, veuillez nous envoyer un courriel à info@empirecomfort.com. Pour toute question d’entretien ou de réparation, veuillez contacter votre concessionnaire. www.empirecomfort.com Page 24 37402-5-0620...

Ce manuel est également adapté pour:

Dvc35sppxlp-1Dvc35ipxnat-1Dvc35sppxnat-1

Table des Matières