WARNING
FIRE OR EXPLOSION HAZARD
If the information in these instructions is
not followed exactly, a fire or explosion may
result causing property damage, personal
injury or loss of life.
— Do not store or use gasoline or other
flammable vapors and liquids in the
vicinity of this or any other appliance.
— WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch;
do not use any phone in your building.
Leave the building immediately.
Immediately call your gas supplier
from a neighbor's phone. Follow
the gas supplier's instructions.
If you cannot reach your gas
supplier, call the fire department.
— Installation and service must be
performed by a qualified installer,
service agency or the gas supplier.
INSTALLATION INSTRUCTIONS
AND OWNER'S MANUAL
VENTED ROOM
HEATER MODELS
RH-25-8
INSTALLER:
Leave this manual with the appliance.
CONSUMER:
Retain this manual for future reference.
WARNING
If not installed, operated and maintained
in accordance with the manufacturer's
instructions, this product could expose you
to substances in fuel or from fuel combustion
which can cause death or serious illness.
RH-35-7
Page 1

Publicité

Chapitres

loading

Sommaire des Matières pour Empire Heating Systems RH-25-8

  • Page 1 INSTALLATION INSTRUCTIONS AND OWNER'S MANUAL VENTED ROOM HEATER MODELS RH-25-8 RH-35-7 INSTALLER: Leave this manual with the appliance. CONSUMER: Retain this manual for future reference. WARNING FIRE OR EXPLOSION HAZARD WARNING If the information in these instructions is If not installed, operated and maintained...
  • Page 2: Table Des Matières

    TABLE OF CONTENTS SECTION PAGE IMPORTANT SAFETY INFORMATION ........................3 SAFETY INFORMATION FOR USERS OF PROPANE GAS ..................4 INTRODUCTION..............................5 - 6 SPECIFICATIONS ................................6 GAS SUPPLY ................................7 CLEARANCES ................................8 VENTING ..................................8 VENTING GUIDELINES ...............................9 VENT SAFETY SHUTOFF SYSTEM ..........................10 REVERSIBLE VERTICAL OR HORIZONTAL DRAFT DIVERTER ................10 THERMOSTAT OPERATION ............................10 LIGHTING INSTRUCTIONS ............................11 PILOT FLAME CHARACTERISTICS ..........................12...
  • Page 3: Important Safety Information

    IMPORTANT SAFETY INFORMATION THIS IS A HEATING APPLIANCE DO NOT OPERATE THIS APPLIANCE WITHOUT FRONT PANEL INSTALLED. • Due to high temperatures, the room heater should control compartments, burners and circulating air be located out of traffic and away from furniture passageways of the room heater be kept clean.
  • Page 4: Safety Information For Users Of Propane Gas

    SAFETY INFORMATION FOR USERS OF PROPANE GAS Propane is a flammable gas which can cause fires and explo- the members of your household. Someday when there may sions. In its natural state, propane is odorless and colorless. not be a minute to lose, everyone's safety will depend on You may not know all the following safety precautions which knowing exactly what to do.
  • Page 5: Introduction

    INTRODUCTION Introduction The base referred to above does not mean the fire-proof base as Always consult your local Building Department regarding regula- used on wood stoves. The protection is primarily for rugs that may tions, codes or ordinances which apply to the installation of a vented be extremely thick and light-color tile that can discolor.
  • Page 6: Specifications

    INTRODUCTION (CONT'D) When an existing Category 1 heater is removed or replaced, the improperly sized venting system (formation of condensate, leakage, original venting system may no longer be sized to properly vent the spillage, etc.) and shall specify the following test procedure: attached appliances.
  • Page 7: Gas Supply

    GAS SUPPLY checked for leaks by the installer. This should be done with a soap Recommended Gas Pipe Diameter solution watching for bubbles on all exposed connections, and if Schedule 40 Pipe Tubing, Type L unexposed, a pressure test should be made. Pipe Inside Diameter Outside Diameter...
  • Page 8: Clearances

    CLEARANCES Clearances: When facing the front of the room heater the minimum Ceiling 48 inches (122cm). Rear of draft hood 2 inches (51mm). clearances to combustible construction (material) are the following: Open in front to provide service, access, and clearance to com- Right side 6 inches (152mm).
  • Page 9: Venting Guidelines

    VENTING GUIDELINES The installer must consider all of the following venting rules. • Flue pipe MUST always have an upward slope (1/4 inch per foot minimum). • Flue pipe MUST run as directly as possible and have as few elbows as possible. •...
  • Page 10: Vent Safety Shutoff System

    VENT SAFETY SHUTOFF SYSTEM This heater must be properly connected to a venting system. This This room heater is equipped with a vent safety switch. The vent heater is equipped with a vent safety shutoff system. safety switch will cause gas flow to the pilot to “shut off” due to improper venting or a blocked flue.
  • Page 11: Lighting Instructions

    LIGHTING INSTRUCTIONS FOR YOUR SAFETY READ BEFORE LIGHTING WARNING If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. A. This appliance has a pilot which must be lighted by hand. C.
  • Page 12: Pilot Flame Characteristics

    PILOT FLAME CHARACTERISTICS The correct flame will be almost horizontal, blue and will extend past the thermocouple 1/4" (6mm). The flame will surround the thermocouple just below the tip. On Propane Gas slight yellow might occur where the pilot flame and the burner flame meet.
  • Page 13: Maintenance

    MAINTENANCE To Remove Main Burner Cleaning Combustion Chamber Disconnect the thermocouple and pilot supply line at the pilot A qualified serviceman should remove the chamber and apply air burner. pressure to the inside in order to clear all passageways. Unscrew the nut on the orifice fitting union. Orifice fitting is Oiling threaded into the main burner.
  • Page 14: Parts List

    P8635 Main Burner Orifice, (RH-35-7 Natural) R1630 ECO Adaptor P8643 Main Burner Orifice,(RH-25-8 Natural) P8651 Main Burner Orifice, (RH-35-7 Propane) P8654 Main Burner Orifice, (RH-25-8 Propane) 29089 Inlet Tubing Assembly RH818 Diverter Assembly RH801 Down Draft Shield RH799 Diverter Plate...
  • Page 15: Parts View

    PARTS VIEW INSULATION 38151-4-0320 Page 15...
  • Page 16: Optional Blower Installation Instructions

    OPTIONAL BLOWER OPTIONAL BLOWER DRB-1 Vented Room Heaters INSTALLATION RH-25 and RH-35 Direct Vent Wall Furnaces INSTRUCTIONS DV-25-SG, DV-35-SG INSTRUCTIONS MUST BE LEFT WITH THE OWNER FOR FUTURE REFERENCE AFTER INSTALLATION Installing Optional DRB-1 Blower steps to reassemble the wiring harness. 1.
  • Page 17 Wiring The appliance, when installed, must be electrically grounded in accordance with local codes or, in the absence of local codes, with the National Electrical Code, ANSI/NFPA 70 or Canadian Electrical Code, CSA C22.1, if an external electrical source is utilized. This appliance is equipped with a three-prong [grounding] plug for your protection against shock hazard and should be plugged directly into a properly grounded three-prong receptacle.
  • Page 18: Master Parts Distributor List

    MASTER PARTS DISTRIBUTOR LIST To Order Parts Under Warranty, please contact your local Empire dealer. See the dealer locator at www.empirecomfort. com. To provide warranty service, your dealer will need your name and address, purchase date and serial number, and the nature of the problem with the unit.
  • Page 19: Warranty

    WARRANTY Empire Comfort Systems Inc. warranties this space heating product to be free from defects at the time of purchase and for the periods specified below. Space heating products must be installed by a qualified technician and must be maintained and operated safely, in accordance with the instructions in the owner’s manual.
  • Page 20 Empire Comfort Systems Inc. Belleville, IL If you have a general question about our products, please e-mail us at info@empirecomfort.com. If you have a service or repair question, please contact your dealer. www.empirecomfort.com 38151-4-0320...
  • Page 21: Radiateur Individuelà Air Pulsé Modèles

    INSTRUCTIONS POUR L’INSTALLATION ET MANUEL DU PROPRIÉTAIRE RADIATEUR INDIVIDUEL À AIR PULSÉ MODÈLES RH-25-8 RH-35-7 INSTALLATEUR : Laissez cette notice avec l’appareil. CONSOMMATEUR : Conservez cette notice pour consultation ultériure. AVERTISSEMENT AVERTISSEMENT RISQUE D’INCENDIE OU D’EXPLOSION Si les informations contenues dans ces instructions Si l’installation, l’usage et l’entretien de ce produit...
  • Page 22 TABLE DES MATIÈRES SECTION PAGE INFORMATION IMPORTANTE DE SÉCURITÉ .......................... 3 INFORMATION DE SÉCURITÉ POUR LES UTILISATEURS DE PROPANE ................4 INTRODUCTION ..................................5 - 6 SPECIFICATIONS ................................... 6 ALIMENTATION EN GAZ ................................7 ESPACES LIBRES ..................................8 ÉVACUATION ....................................8 LE SYSTÈME DE FERMETURE DE SÛRETÉ...
  • Page 23: Information Importante De Sécurité

    INFORMATION IMPORTANTE DE SÉCURITÉ CECI EST UN APPAREIL DE CHAUFFAGE NE PAS FAIRE FONCTIONNER CET APPAREIL SANS QUE LA PAROI FRONTALE SOIT INSTALLÉE. • A cause des hautes températures, cet appareil doit être situé • Ne rien mettre autour du radiateur qui pourrait obstruer le dans un endroit non achalandé...
  • Page 24: Information De Sécurité Pour Les Utilisateurs De Propane

    INFORMATION DE SÉCURITÉ POUR LES UTILISATEURS DE PROPANE Le Propane est un gaz inflammable qui peut causer des feux et des puis réexaminez les, point par point avec les membres de votre explosions. Dans son état naturel, le propane est inodore et sans famille.
  • Page 25: Introduction

    INTRODUCTION Introduction Installation sur un Tapis ou Tuile Toujours consulter le département de construction de votre région en ce Si cet appareil est installé directement sur un tapis, tuiles ou tout genre de qui regarde les règlements, les codes ou les ordonnances qui s’appliquent matériel combustible autre qu’un plancher de bois, cet appareil doit être installé...
  • Page 26: Specifications

    INTRODUCTION (suite) Lorsqu’un radiateur de catégorie 1 existant est retiré ou remplacé, le sys- ment indiquer les effets d’un système de ventilation de taille inadéquate tème de ventilation d’origine peut ne plus être dimensionné pour ventiler (formation de condensat, fuite, déversement, etc.) et doivent spécifier la correctement les appareils raccordés.
  • Page 27: Alimentation En Gaz

    ALIMENTATION EN GAZ Les composantes employées sur les joints filetés des tuyaux doivent être Le Diamètre recommandé de tuyau de gaz résistantes à l’action des gaz de pétrole liquéfiés. La canalisation de gaz Le plan 40 tuyau Les tuyaux, Taper L doit être vérifiée par l’installateur pour des possibilités de fuites.
  • Page 28: Espaces Libres

    ESPACES LIBRES Côté droit 6" (15.2cm) Côté gauche 6" (15.2cm) Espaces libres: Lorsque vous êtes devant le radiateur individuel, les espaces Pour l’entretien, nous recommendons 18" (45.6cm) pour le côté gauche. libres minimum aux matériaux combustibles sont les suivants: Ne pas installer dans une niche ou un placard. Aucune saillie horizontale est permise 48"...
  • Page 29: Le Système De Fermeture De Sûreté De L'évent

    LE SYSTÈME DE FERMETURE DE SÛRETÉ DE L’ÉVENT Cet appareil doit être branché correctement à un système d’évacuation. Ce radiateur individuel est muni d’un interrupteur de sûreté de l’évent. Cet appareil est muni d’un système de fermeture de sûreté de l’évent. Lors d’une évacuation inadéquate ou d’une obstruction de la cheminée, l’interrupteur de sûreté...
  • Page 30: Instructions D'allumage

    INSTRUCTIONS D'ALLUMAGE POUR VOTRE SÉCURITÉ, LIRE AVANT D’ALLUMER AVERTISSEMENT Si vous ne suivez pas exactement ces instructions, un feu ou une explosion peut se produire causant des dommages à la propriété, des blessures corporelles ou la mort. A. Cet appareil a une veilleuse qui doit être allumée manuellement. •...
  • Page 31: Aspect Convenable De La Flamme De La Veilleuse

    ASPECT CONVENABLE DE LA FLAMME DE LA VEILLEUSE La flamme sera quasiment horizontale, bleue et s’allongera au-delà du thermocouple de 1/4" (6mm). La flamme entourera le thermocouple juste LA FLAMME DOIT SE PROLONGER en-dessous de la pointe. AU-DELÀ DU THERMOCOUPLE Avec du Gaz Propane, un jaune pâle apparaîtra à...
  • Page 32: Maintenance

    MAINTENANCE Enlever le Brûleur Principal Nettoyage de la Chambre de Combustion Du brûleur de la veilleuse, débrancher le thermocouple et la ligne Un technicien d’entretien qualifié devrait enlever la chambre et appliquer d’alimentation de la veilleuse. une pression d’air à l’intérieur de façon à nettoyer tous les passages. Dévisser l’écrou sur le raccord de l’orifice.
  • Page 33 Cette page a été intentionnellement laissée vierge. 38151-4-0320 Page 13...
  • Page 34: Liste Des Pièces

    R2423 Connecteur, 5/16 tubes x 3/8 NPT Orifice du brûleur principal (RH-35-7 P8635 R1630 Adaptateur ECO Naturel) Orifice du brûleur principal (RH-25-8 P8643 Naturel) Orifice du brûleur principal en Cuivre P8651 (RH-35-7 Propane) Orifice du brûleur principal en Cuivre P8654...
  • Page 35: Vue Des Pièces

    VUE DES PIÈCES INSULATION 38151-4-0320 Page 15...
  • Page 36 SOUFFLERIE FACULTATIVE SOUFFLERIE FACULTATIVE DRB-1 INSTRUCTIONS POUR Appareils de Chauffage à Évacuation Indirecte RH-25 et RH-35 L'INSTALLATION Radiateurs Muraux à Évacuation Directe R-2115-F DV-25-SG, DV-35-SG AUGUST 2005 APRÈS L’INSTALLATION, L’INSTALLATEUR DOIT LAISSER LE MANUEL D’INSTRUCTIONS AU PROPRIÉTAIRE. Installation de la Soufflerie Facultative DRB-1 ATTENTION: Le harnais de fils électriques sur la soufflerie est 1.
  • Page 37 Pose des Fils Électriques BLANC Si vous utilisez une source électrique extérieure, l’appareil, lorsqu’il NOIR NOIR est installé, doit avoir une prise de terre conforme avec les codes locaux ou dans l’absence de codes locaux, avec le National Electri- cal Code, ANSI/NFPA70 ou Canadian Electrical Code, CSA C22.1. Pour votre protection contre les dangers de chocs, cet appareil est muni d’une fiche à...
  • Page 38: Liste Des Distributeurs De Pièces Principaux

    LISTE DES DISTRIBUTEURS DE PIÈCES PRINCIPAUX Pour commander des pièces sous garantie, adressez-vous au revendeur Empire local. Veuillez voir le concessionnaire au www.empirecomfort.com. Pour assurer un service sous garantie, le revendeur doit connaître votre nom, votre adresse, la date d’achat et le numéro de série du produit, ainsi qui la nature du problème. Pour commander des pièces après expiration de la période de garantie, veuillez communiquer avec votre revendeur ou avec l’un des distributeurs de pièces principaux indiqués ci-dessous.
  • Page 39: Garantie

    GARANTIE Empire Comfort Systems Inc. garantit que ce produit de chauffage individuel est exempt de défauts au moment de son achat et pen- dant les périodes indiquées ci-dessous. Les produits de chauffage individuel doivent être installés par un technicien qualifié et doivent être entretenus et utilisés de façon sécuritaire, en conformité...
  • Page 40 Empire Comfort Systems Inc. Belleville, Illinois Pour toute question générale concernant nos produits, veuillez nous envoyer un courriel à info@empirecomfort.com. Pour toute question d’entretien ou de réparation, veuillez contacter votre revendeur. www.empirecomfort.com 38151-4-0320...

Ce manuel est également adapté pour:

Rh-35-7