Metabo HPT STRAP-TITE NR 3665DA Manuel D'instructions Et De Sécurité page 30

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

English
PROBLEM
Nails jam.
Driven nail is bent.
Nail not driven into hole.
2. Charger
PROBLEM
The charge indicator lamp is rapidly
fl ickers purple, and battery charging
doesn't begin.
The charge indicator lamp blinks red,
and battery charging doesn't begin.
Battery usage time is short even
though the battery is fully charged.
The battery takes a long time to
charge.
The USB power lamp has switched
off and the USB device has stopped
charging.
USB power lamp does not switch
off even though the USB device has
fi nished charging.
It is unclear what the charging status
of a USB device is, or whether its
charging is complete.
30
CHECK METHOD
Check for proper nails.
Driver blade worn or damaged?
Probe not positioned over hole
Probe is damaged or worn.
Nail support (B) is damaged.
(Refer to pages 2, 2)
Blockage due to debris
CHECK METHOD
The battery is not inserted all the way. Insert the battery fi rmly.
There is foreign matter in the battery
terminal or where the battery is
attached.
The battery is not inserted all the way. Insert the battery fi rmly.
The battery is overheated.
The battery's life is depleted.
The temperature of the battery,
the charger, or the surrounding
environment is extremely low.
The charger's vents are blocked,
causing its internal components to
overheat.
The cooling fan is not running.
The battery's capacity has become
low.
The USB power lamp lights up green
to indicate that USB charging is
possible.
The USB power lamp does not switch
off even when charging is complete.
CORRECTION
Use only recommended nails.
Contact metabo HPT for inspection.
Position the probe in the hole before
fi ring.
Contact metabo HPT for inspection.
Contact metabo HPT for inspection.
Remove debris.
(Refer to page 25)
CORRECTION
Remove the foreign matter.
If left alone, the battery will
automatically begin charging if its
temperature decreases, but this may
reduce battery life. It is recommended
that the battery be cooled in a well-
ventilated location away from direct
sunlight before charging it.
Replace the battery with a new one.
Charge the battery indoors or in
another warmer environment.
Avoid blocking the vents.
Contact a metabo HPT Authorized
Service Center for repairs.
Replace the battery with one that has
capacity remaining.
Plug the charger's power plug into an
electric socket.
This is not a malfunction.
Examine the USB device that is
charging to confi rm its charging
status.

Publicité

Table des Matières
loading

Table des Matières