Maintenance Log; Checking Engine Oil Level; Engine Oil Recommendations - Generac GH-410 Manuel Du Propriétaire

Masquer les pouces Voir aussi pour GH-410:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Section 4: Maintenance

Maintenance Log

Battery inspection and charge check
Dates Performed:
Oil, oil filter, air filter and spark plug replacement
Dates Performed:
Valve Adjustment
Dates Performed:

Checking Engine Oil Level

WARNING
Risk of burns. Allow engine to cool before
draining oil or coolant. Failure to do so
could result in death or serious injury.
WARNING
Skin irritation. Avoid prolonged or repeated contact with
used motor oil. Used motor oil has been shown to cause
skin cancer in laboratory animals. Thoroughly wash
exposed areas with soap and water.
CAUTION
Engine damage. Verify proper type and quantity of
engine oil prior to starting engine. Failure to do so
could result in engine damage.
When power outages necessitate running the generator
for extended periods, the oil level should be checked
daily. To check the engine oil level:
If the generator is running during a utility outage,
1.
first turn OFF all associated loads running in the
residence
using
18
(000139)
(000210)
(000135)
the
electrical
panel
disconnect. Then, turn the generator main circuit
breaker to the OFF position.
Press the control panel OFF button. Wait 5
2.
minutes.
Remove the dipstick and wipe it dry with a clean
3.
cloth.
Completely insert the dipstick and again remove it.
4.
Observe the oil level. The level should be at the
5.
"FULL" mark on the dipstick.
If necessary, remove the oil fill cap and add oil to
6.
the engine until the level reaches the "FULL" mark
and reinsert the dipstick and fill cap.
Press the control panel AUTO button.
7.
If the generator was running during a utility outage,
8.
first turn the main circuit breaker to the ON
position. Then, turn ON the needed loads in the
residence.

Engine Oil Recommendations

To maintain the product warranty, the engine oil should
be serviced in accordance with the recommendations of
this
Manual.
Maintenance Kits are available that include engine oil, oil
filter, air filter, spark plug(s), a shop towel and funnel.
These kits can be obtained from an Independent
Authorized Service Dealer (IASD).
main
Owner's Manual for 60 Hz Air-cooled Generators
For
your
convenience,
Generac

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Gh-530Gt-990Gt-999

Table des Matières