4.1. Configuration example intercom
station
It has been decided to use a Behnke Series
10 Intercom with two direct call buttons.
The Behnke device has been installed and
connected to an extension of the telephone
system with the relay wired to hold the open
door function. Pressing direct call button 1
shall establish a connection to the reception
(extension 111) and pressing direct call
button 2 shall establish a connection to the
warehouse (extension 222). Entering code
99 shall open the door and the relay shall
be activated for 3 seconds. Additionally, the
volume shall be increased slightly and to
prevent unauthorised access, the security
code shall be changed to 1234.
Starting from the default settings, the fol-
lowing configurations need to be changed:
*
0000
21 111#
22 222#
09 3 #
10 99 #
06 8 #
01 1234 1234 #
*
www.behnke-online.com
Configuration and Set-up
▸
Enter set-up mode
▸
Enter the security code
▸
Save telephone no. 111 for direct call button 1
▸
Save telephone no. 222 for direct call button 2
▸
Change the activation interval for the relay to
open the door to 3 seconds
▸
Change the default activation code for the
relay to 99
▸
Change the volume to value 8
▸
Change the security code to 1234
▸
Exit set-up mode
Instructions for Series 10
GB