Fan Operation; Auto Mode; Cooling Operation - Royal Sovereign ARP-912 Guide D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

PRODUCT OPERATION
Boot State:
When you select a mode, the machine will enter boot state. The front display, as well as the indicator
light of the mode selected will blink for a few seconds to allow the machine to process the selection.
Once the machine has processed the change, the indicator light will turn solid and the new mode will
begin.

Fan Operation:

In the boot state, press the mode icon to switch to fan mode. The front display, as well as the indicator
light will blink for a few seconds when selected and turn solid when confirmed.
In fan mode, the upper blower works and the compressor does not work.
Press the wind speed icon to switch between high and low wind speeds.

Auto Mode:

In the boot state, press the mode icon to switch to automatic mode. The front display, as well as the
indicator light will blink for a few seconds when selected and turn solid when confirmed.
When the machine is powered on for the first time or if the machine has been off for more than 30
minutes, the machine enters automatic mode by default.
In auto mode the machine will automatically set to the following:
If room temperature is > 75°F (24°C) machine will enter cooling operation
If room temperature is > 72°F (22°C) and < 75°F (24°C) machine will enter fan operation
If room temperature is < 72°F (22°C) machine will enter single cold type ventilation
Once in automatic mode, the room temperature will change, while the set operation will remain the
same. The set operation will not change until automatic mode is switched to another mode or turned off.

Cooling Operation:

In the boot state, press the mode icon to switch to cooling mode. The front display, as well as the
indicator light will blink for a few seconds when selected and turn solid when confirmed.
Press the increase or decrease icons to set the desired temperature. The temperature range is from
59-88°F (15-31°C). The front and top digital displays will show the current set temperature.
Once the room has reached the desired temperature, the machine will turn off the compressor and run in
fan operation.
Press the wind speed icon to switch between high and low wind speeds.
For optimal operation, shorten the length of the air duct and keep from direct sunlight.