6
Press the button to start the closing phase
7
Press the button again to define the point from where you
want the door to slow down; otherwise, skip to the next
step. (DIP 5-ON)
8
Wait for the automation to stop automatically
9
Disconnect the power supply to the control unit.
Set DIP switch 9 to OFF
10
Power the control unit
9.2.
Partial opening learning phase
Cut off power to the control unit.
1
Set the DIP 9 switch to ON
Power the control unit
2
Press the N.O. button connected to terminals 16 and 17. The automation should start
3
Press to define the opening partial position
4
Press the button to start the closing phase
5
Wait for the automation to stop automatically
6
Cut off power to the control unit.
7
Set the DIP 9 switch to OFF
Power the control unit
8
The COMMISSIONING ends once the SELF-LEARNING phase of the WISLIDE 500KG
automation is complete.
If you notice a continuous ticking during operation, press the P1 PUSH BUTTON during
closing.
IF YOU DO NOT USE THE ENCODER: carry out the learning phase with the
speed trimmers already set correctly.
The
automation
CLOSING
The
automation
DOWN
The automation is in the
CLOSED position
Learning phase complete
Automation must be in the
CLOSED position.
in the OPENING. Otherwise,
invert the wires of Terminal 3
and 4 and resume from point
1.
The automation STOPS
Automation starts CLOSING
Automation is in the CLOSED
Learning phase completed
Page 21
starts
in
SLOWS