8.11.
Electric lock connection
8.11.1
Normally closed electric latch deadbolt
By setting DIP 3 to OFF it is possible to connect the electro-safety piston with latch (optional
item code 1122.59) of type N.C. (normally closed) making the connections as shown below
8.11.2
Mechanical or electromagnetic NC (normally closed) locks.
By setting DIP 3 to ON it is possible to connect the N.C. (normally closed) mechanical or
electromagnetic, by setting DIP 6 to ON a 2 sec advance is obtained on the electric lock
opening by making the connections as shown below.
Page 18