8.8.
Push button connection
The connection can be made to any push button or NO (normally open) contact, by connecting
the contact to terminals 15 and 17 of the control unit.
8.9.
Button connection for partial opening
The connection can be made to any button or N.O. (normally open) contact, connecting the contact
to terminals 16 and 17 of the control unit.
.
8.10.
Antenna connection
You can connect a radio antenna by making the following connections. Connect the motor power
cable to terminals 3 and 4 of the control unit.
Page 16
- ENCODER power supply
Encoder signal
+ 5V ENCODER power supply
NO push
button
Coaxial cable
braided wire
= WHITE
= GREEN
= BROWN