Motor Connection; Encoder Connection - Master FORCE 450 N Manuel D'utilisation Et D'installation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

8.6.

Motor connection

Connect the motor power cable to terminals 3 and 4 of the control unit.
Pay attention not to reverse the OPEN and CLOSE poles.
MOTOR
8.6.1. Motor connection for recessed mounting and Right-hand opening
Connect
• the blue motor cable to terminal 3 of the control unit
• the red motor cable to terminal 4 of the control unit
8.6.2. Motor connection for recessed mounting and Left-hand opening
Connect
• the red motor cable to terminal 3 of the control unit
• the blue motor cable to terminal 4 of the control unit
8.7.

Encoder connection

The system can be used with or without the encoder. For more sturdiness, we recommend using
it with the encoder.
Connect:
• the brown encoder cable to terminal 19 (+5V) of the control unit;
• the green encoder cable to terminal 20 (signal) of the control unit;
• the white encoder cable to terminal 21 (-5V) of the control unit.