Dip B Operating Logic; Start-Up And Programming; Learning Phase - Master FORCE 450 N Manuel D'utilisation Et D'installation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

5-ON
6-OFF
7-ON
8-OFF
9-ON
9-OFF
10-OFF
8.13.

DIP B operating logic

1-ON
1-OFF
2-ON
2-OFF
3-ON
3-OFF
4-ON
4-OFF
All dip-switches must be set to ON. (typic Master installation)

9. START-UP AND PROGRAMMING

If everything is correctly connected, after switching the electronic board on, LED L1 should flash,
while the LEDs of the STOP, PHOTO, OLS, CLS inputs should be lit.
The START and CLOSE LEDs should be off.
9.1.

Learning phase

1
Disconnect the power supply to the control unit.
Set DIP switch 9 to ON
2
Power the control unit
3
Press the NO push button connected to terminals 15 and 17.
4
Press the button again to define the point from where you
want the door to slow down; otherwise, skip to the next
step. (DIP 5-ON)
5
The automation opens unit it reaches the end of its stroke
(mechanical stop)
Page 20
Enable acceleration and deceleration ramp settings
Deactivation of the electric lock opening advance
Enable encoder input
Delay in transmitting the opening command disable
Only during the learning phase (as described below)
During normal operation
Not used
STOP
PHOTO
OLS
CLS
It disables the STOP input
It enables the STOP input
It disables the PHOTO input
It enables the PHOTO input
It disables the OLS input
It enables the OLS input
It disables the CLS input
It enables the CLS input
The automation must be set
to CLOSED.
The automation should start in
OPENING; otherwise, reverse
the wires of terminals 3 and 4
and start again from point 1.
The
automation
DOWN
The automation STOPS
SLOWS

Publicité

Table des Matières
loading

Table des Matières