GB
FR
DE
ES
ASSEMBLY
PRESSURE CLAMP ASSEMBLY (Fig. 6)
PRESSURE CLAMP
Screw the small guard post securely into one of the
Q
threaded holes on the top of the left / right side of the
fence.
Loosen the black color lock screw by turning the screw
Q
counterclockwise.
Slide the connection ring over the small guard post
Q
and tighten lock screw.
Note: Set the proper height between the press
plate and the wood piece before routing.
MITRE GAUGE / FEATHER
BOARD ASSEMBLY (Fig. 7)
MITRE GAUGE
Assemble protractor and gauge.
Q
Position the pointer so that it is perpendicular to the
Q
scale on the protractor. Locate the #6 pan head screw
and feed it through the hole in the pointer and into the
threaded hole in the protractor. Tighten using a flat
head screwdriver.
Slide entire mitre gauge assembly into mitre gauge
Q
track.
FEATHER BOARD
Place the router table right side up with the front edge
Q
closest to you.
Position the feather board on the table with the two
Q
black knobs facing you.
Align the knob with the appropriate holes in the table
Q
and screw in to secure feather board. For smaller
workpieces use the holes nearest the cutter.
WARNING
Failure to unplug your router table could result
in accidental starting causing possible serious
personal injury.
WARNING
Do not wear loose clothing or jewelry when
operating table mounted router. They could get
caught in moving parts causing serious injury.
Keep head away from router and routing area.
Hair could be drawn into rotating bit causing
serious injury.
IT
NL
PT
DK
SE
FI
NO
RU
PL
CZ
English
ATTACH ROUTER TO TABLE (Fig. 8)
Carefully turn the table right side up and check to
Q
make sure it rests on all four legs and does not rock.
Locate the nine counter sunk holes surrounding the
throat of the table.
Using a screw driver, remove the screws holding
Q
the plate to the base of the router and retain. Do not
discard the base plate or screws as they may be
required for future use when routing by hand.
With the base plate removed from the router, hold the
Q
router upside down so that the flat edge of the router
base is facing the front of the table. Align holes in the
table with the corresponding thread holes in the base
of the router. Holding the router with one hand, use
the other hand to securely tighten each screw.
Use the screws to fix the router
Q
Model
ERT-1150VN
ERT-1150V
ERT-2100V
ERT-1500V
MOUNTING TO A STABLE WORK
SURFACE (Fig. 9 & 10)
Place the router table right side up with the front edge
Q
closest to you.
WARNING
All four legs must be securely bolted to a stable
worksurface. Failure to heed this warning could
result in serious personal injury.
WARNING
Check extension cords before each use. If
damaged,replace immediately. Never use
tool with a damaged cord since touching the
damaged area could cause electrical shock,
resulting in serious injury.
OPERATION
WARNING
Your router or router table should never
be connected to a power supply when you
are assembling parts, making adjustments,
installing or removing cutters, or when not in
use. Disconecting your router table will prevent
accidental starting that could cause serious
injury.
4
HU
RO
LV
LT
EE
Screw specification
M4x20
M4x20
M6x30
5/16 x 1in
HR
SI
SK
GR
TR
Quantity
4pce
4pce
3pce
2pce