Replace or turn vacuum lips
1 Wear indicator
2 Vacuum lip
The vacuum lips must be replaced or re-
versed if they are worn down to the wear in-
dicator.
Remove the vacuum bar.
Unscrew the star grips.
Remove the plastic parts.
Remove the vacuum lips.
Insert new or reversed vacuum lips.
Insert the plastic parts.
Screw in and tighten the star grips.
Clean water distribution channel
Remove the rubber strip and clean the
channel with a cloth. After cleaning, re-
place the rubber strip evenly.
Replacing the brush rollers
Lift the cleaning head.
1 Unlocking key, storage cover
2 Brush
3 Push button
18
Press the release button of the storage
cover.
Swivel the storage cover to the side.
Pull out the brush rollers.
Note:
Replace the roller brushes when the bristle
length has reached 10 mm
Insert new brush rollers.
Swivel the storage cover back and
press it closed on the push button.
Replacing the disk brushes
Lift the cleaning head.
Press the pedal for changing the brush-
es downward beyond its resistance.
Pull the disc brush out of the side below
the cleaning head.
Hold the new disc brush under the
cleaning head, push upward and lock.
Install cleaning head
Push the appliance forward about 2 m
so that the steering rollers point toward
the rear.
Press the pedal for lowering the clean-
ing head downwards slightly and then
move it to the left. This unlocks the ped-
al. Release the pedal slowly upwards.
The lift arm of the cleaning head will be
lowered.
1 Spring element
2 Locking pin
3 Terminal strip cover
4 Lock of safety pin
5 Excenter lever
Remove the terminal strip cover.
Place the cleaning head halfway in front
of the appliance.
Connect the mains supply cable of the
1
cleaning head to the appliance.
Attach the terminal strip cover.
Connect the hose couplers on the
cleaning head to the hose on the appli-
2
ance.
3
6
-
EN
1 Push handle
2 Cleaning head
Insert the push bow into the cleaning
head intake.
1 Safety splint
Insert the locking pins from below into
the mount of the cleaning head.
1 Safety splint
2 Linch pin
Insert the linch pin through the locking
pins and fold the locking rings forward.
1 Excenter lever
2 Locking pin
Open the excenter lever of the slideable
intake on the lift arm.
Press the cleaning head all the way
against the push handle.
Note: The less play the cleaning head
has after being installed, the less vibra-
tion will occur during cleaning.
Move the intake and insert the safety
pin and lock it into place.
Close the excenter lever.
Swivel the water reservoir all the way
down, check the lock.