venting
EN
These vent kits allow for either horizontal or vertical venting of the appliance. The maximum allowable horizontal run is 20
feet (6.1m). The maximum allowable vertical vent length is 40 feet (12.2m). The maximum number of vent connections is two
horizontally or three vertically (excluding the appliance and the air terminal connections) when using fl exible venting.
Deviation from the minimum vertical vent length can create diffi culty in burner start-up and / or carboning. Use an
adjustable pipe as the fi nal length of rigid piping to the stove for ease of installation.
2.1

typical vent installation

34" (86.4cm)
Maximum
29" (73.7cm)
Minimum
10
W415-2339 / D / 02.04.22
55 3/4" (141.6cm)
Minimum
Plus Rise *
* See "venting section".
16" (40.6cm)
Minimum
40 ft (12m)
Maximum
3 ft (1m)
Minimum