gala gar GALA 1700 G.E. TIG PULSE Manuel Technique D'instructions page 21

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

3.8 ADJUSTMENT AND MEMORISATION OF PARAMETERS.
The possible values for each parameter appear in section 4, as well as which work modes they are available in. To
set and memorise the parameters the following steps must be taken:
• Select the desired work mode with pushbutton G (2-S, 4-S...)
• With pushbutton J, select the parameter you wish to set.
• The current value will appear on the display. With F vary the value until the desired value is reached.
• Continue pressing G and carry out the same operation with the other parameters.
• Once an appropriate welding mode (JOB) has been configured and you wish to keep them for later jobs,
they can be memorised. Press JOB 1 or JOB 2 for a few seconds until the relative LED lights up.
• To recuperate the memorised values, press JOB 1 or JOB 2.
• Bear in mind that the JOB values are different in each work mode (2-S LIFT, 2-S HF, 4-S HF and 4-S
ESPECIAL). There is a total of 8 memories.
• To clear all the memories and parameters of a certain mode just press the JOB 1 and JOB 2 keys once.
• To clear all the memories and parameters just press the JOB 1 and JOB 2 keys once, whilst the machine is
connected.
3.9 USE OF REMOTE CONTROL IN TIG PROCESS. TIG 2000 P CONTROL.
The equipment has pedal, TIG 2000 P, which enables the equipment to be regulated with your foot.
procedure is as follows:
Connect pedal TIG 2000 P to connector
Indication
must light up, indicating that the pedal is connected.
G
With selector
choose TIG procedure 2-S HF
The pedal will adjust between the maximum current chosen
.
(
)
When the pedal is pressed, it is possible to strike in LIFT ARC or HIGH FREQUENCY.
Indication
must light up, indicating the presence of no-load tension.
Using the pedal, select the desired intensity. REMEMBER that the pedal regulates between the minimum
current programme in start current and maximum set in the equipment (
When you work in 2-S and you release the pedal, the down ramp will start.
It is possible to add the pulsed arc selection.
GALA G.E. TIG PULSE
M
or 2-S LIF
I
(
2
. (It can also be used in 4-S mode)
and the minimum current memorised in
)
-
).
I
I
s
2
21
The
I
s

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Gala 2000 g.e. tig pulse

Table des Matières