Maintenance
Before cleaning the fryer, always remove the plug from the socket.
Never immerse the deep fryer in water or other cleansing agents.
The deep fryer can be cleaned with a damp cloth.
Do not use aggressive or caustic cleansing agents.
Wherever possible, avoid water coming into contact with electrical components.
Faults:
Fault
Symptom
Appliance
does not do
anything
Appliance
does not
reach the set
temperature.
1) Reset overload circuit breaker
- Allow the deep fryer to cool down.
- Remove the element holder from the support.
- Unscrew the black protective cap from the bottom of the element holder.
- Press the "reset button" of the overload circuit breaker. You should hear a clear click.
- Screw the black protective cap back on
- Reinstall the element holder on the support.
Cause
Orange lamp
does not light
No mains voltage
Green lamp
does not light
Overload circuit
breaker tripped.
Element holder is not
Orange lamp
correctly positioned on
lights
the support
Green lamp
Thermostat defective
does not light
Overload circuit
breaker defective
Element defective
Micro switch defective
Thermostat defective
Long frying time.
Green lamp
Element defective
does not light
Possible solution
Check the electrical
installation.
Reset the overload circuit
breaker.
See note 1)
Install the holder on the
support. See installation.
Replace the thermostat.
Replace the overload circuit
breaker.
Replace the element.
Replace the micro switch.
Replace the thermostat.
Replace the element.