Function
AC Voltage
(V AC)
DC Voltage
(V DC)
Input Impedance: 10M
Frequency Range: 45 to 400Hz
Maximum Input: 600V AC RMS or 600V DC
AC Current
(A AC)
Frequency Range: 50 to 60Hz
Resistance
Maximum Input: 600V AC RMS or 600V DC
OTHER MEASUREMENT APPLICATIONS
Maximum Input: 600V DC or 600V AC RMS
• Continuity Check: Audible signal <10Ω, max current 1.5mA
• Sampling Frequency: Approx. 3 samples per second
• Auto Power off: After ~15 minutes of inactivity
• Overload: "OL" indicated on display
• Polarity: "-" on display indicates negative polarity
• Display: 3 ½ digit, 2000 Count LCD
ELECTRICAL SPECIFICATIONS
Range
200.0mV
2.000V
20.00V
200.0V
600V
200.0mV
2.000V
20.00V
200.0V
600V
2.000A
20.00A
200.0A
400A
200.0
2.000K
20.00k
200.0k
2.000M
20.00M
Resolution
0.1mV
1mV
10mV
100mV
1V
0.1mV
1mV
10mV
100mV
1V
1mA
10mA
100mA
1A
0.1
1
10
100
1k
10k
Accuracy
±(2.5% + 10 digits)
±(2.0% + 5 digits)
±(1.0% + 8 digits)
±(1.0% + 3 digits)
±(2.5% + 30 digits)
±(2.0% + 10 digits)
±(1.2% + 5 digits)
±(1.2% + 3 digits)
±(2.0% + 5 digits)
3