General Specifications; Electrical Specifications - Klein Tools CL312 Manuel D'instructions

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

ENGLISH

GENERAL SPECIFICATIONS

Klein Tools CL312 is an automatically ranging true root mean square
(TRMS) digital clamp meter that measures AC current via the clamp,
AC/DC voltage, DC microamps, resistance, continuity, frequency,
capacitance, and tests diodes via test-leads, and temperature via a
thermocouple probe.
• Operating Altitude: 6562 ft. (2000m)
• Relative Humidity: <95% non-condensing
• Operating Temp: 32° to 122°F (0° to 50°C)
• Storage Temp: 14° to 122°F (-10° to 50°C)
• Accuracy: Values stated at 65° to 83°F (18° to 28°C)
• Temp Coefficient: 0.1 x (Quoted Accuracy) per °C above
28°C or below 18°C, corrections are required when ambient
working temp is outside of Accuracy Temp range
• Dimensions: 8.66" x 3.03" x 1.61" (220 x 77 x 41 mm)
• Weight: 9.88 oz. (280 g) including batteries
• Calibration: Accurate for one year
• Standards: Conforms to: UL 61010-1, UL 61010-2-032,
UL 61010-2-033.
Certified to: CAN/CSA C22.2 NO. 61010-1,
61010-2-032, 61010-2-033, IEC EN 61010-1,
61010-2-032, 61010-2-033, IEC EN 61326-1.
• Pollution degree: 2
• Accuracy: ± (% of reading + # of least significant digits)
• Drop Protection: 3.3 ft. (1m)
• Safety Rating: CATIII 600V, Class 2, Double insulation
• Electromagnetic Environment: IEC EN 61326-1. This
equipment meets requirements for use in basic and controlled
electromagnetic environments like residential properties,
business premises, and light-industrial locations.
Specifications subject to change.
2

ELECTRICAL SPECIFICATIONS

Function
Range
400.0mV
4.000V
AC Voltage
40.00V
(V AC)
400.0V
600V
400.0mV
4.000V
DC Voltage
40.00V
(V DC)
400.0V
600V
Input Impedance: 10MΩ
Frequency Range: 45 to 400Hz
Maximum Input: 600V AC RMS or 600V DC
4.000A
AC Current
40.00A
(A AC)
400.0A
Frequency Range: 50 to 60Hz
DC Microamps
200 μA
(µA DC)
Maximum Input: 600V AC RMS or 600V DC
400.0Ω
4.000KΩ
40.00kΩ
Resistance
400.0kΩ
4.000MΩ
40.00MΩ
Maximum Input: 600V AC RMS or 600V DC
Resolution
Accuracy
0.1mV
±(1.8% + 5 digits)
1mV
±(1.5% + 5 digits)
10mV
±(1.2% + 5 digits)
100mV
1V
±(1.5% + 5 digits)
0.1mV
±(1.0% + 8 digits)
1mV
10mV
±(0.8% + 3 digits)
100mV
1V
±(1.0% + 3 digits)
1mA
±(2.5% + 30 digits)
10mA
±(2.5% + 10 digits)
100mA
±(2.0% + 10 digits)
0.1 μA
±(1.0% + 5 digits)
0.1Ω
±(1.2% + 5 digits)
10Ω
±(1.2% + 3 digits)
100Ω
1kΩ
10kΩ
±(2.0% + 5 digits)
3

Publicité

Table des Matières
loading

Table des Matières