7. Operation
Setting the tolerance plate
Using the threaded studs with spring elements, move the
tolerance plates to the required dimension points.
Repeat process on opposite side.
Note
en
Please note that the positions of the tolerance
i
plates as well as the number of tolerance
plates must be matched to the depth of the
drawer that is being assembled.
Setting rear panel and drawer side profile heights
Pull out latch bolts and move stop to the required rear panel
or drawer side profile height.
Repeat process on opposite side.
22
Positioning pressing in cylinder for drawer side panel
Undo eccentric tensioner, move to the required drawer side
profile depth and retighten tensioner.
Repeat process on opposite side.
Note
The values on the "tolerance bar" scale,
i
the "drawer depth stop" scale and the
"Positioning side profile pressing on cylinder"
scale must agree!