The device is a self-powered siren with a neodymium dynamic
magnetic diffuser, in plastic housing with metal shielding. It has
a fl ashing LED-light, system status indicator and programmable
inputs, with integrated confi gurable pull-ups to allow control via
open collector outputs.

TECHNICAL CHARACTERISTICS

Power supply
min 11.5 V, max 14.5 Vdc
5 mA in standby (not including battery), 1.9 A in
Absorption
alarm with siren and fl ashing light, 2.25 A at inrush
Battery polarity reversal
via 10 A rapid fuse (F1)
12 V 2.0 A/h battery
Battery
(not included - cod. 20022204)
Sound power
120 dB at 1 m (neodymium diffuser)
Max. ringtone time
6 minutes
1 fl ashing light for alarm indication and 1 system
Indications
status LED
Housing
plastic with internal metal protection
Colours available
white, grey and chrome
container anti-tear and anti-removal tamper
Protection
protection
3 coloured LEDs for system status and partial
Indications
control indication
electromagnetic compatibility:
Applicable standards
EN 50081-1 (interference emission)
and EN50082-2 (resistance to interference)
Approvals
CE
Operating temperature
0° to 50°C
Storage temperature
-10° to +70°C
Relative air humidity
5 to 95% with no condensation
Dimensions
298x229x126mm

CONNECTION TERMINALS

+12V
Power supply positive pole
-12V
Power supply negative pole
COM ALL
Alarm lock indication (set PALL and ALL jumpers)
COM LED
System LED control indication (set PLED and LED jumpers)
Service indication: if set to 12 V, locks alarms and resets the alarm
ING. TEST
memory
TAMPER
Tamper contact terminals
JUMPERS AND CONNECTORS
Determines to which COM ALL terminal condition the alarm status corresponds.
ALL
If open, the alarm corresponds to a lack of voltage on the terminal.
If closed, the alarm corresponds to detected voltage on the terminal.
PALL
If closed, the command on ALL is with GND; if open, with +12V.
Determines to which COM LED terminal condition the system deactivated
status corresponds. If open, the deactivated condition corresponds to
LED
detected voltage on the terminal. If closed, the deactivated condition
corresponds to a lack of voltage on the terminal.
PLED
If closed, the command on LED is with GND; if open, with +12V.
Determines alarm memory exclusion. If open, the alarm memory is
BIT
excluded; if closed, the alarm memory is present.
Connector used to connect the anti-foam device required to protect the
M3
siren from all attempts to mask/tamper with the sound system (if not used,
leave the terminals jumpered).
P1
Connector for LED card (already connected).
AP
Sound diffuser connection terminal (already connected).
BATT.
Pre-wired cables for backup battery connection.
4
STARTUP
The fi rst time the device is powered up, the LEDs inside the fl ashing light come on steadily
for 2s, then the siren emits a steady tone at full volume for approximately half a second,
and fi nally all the LEDs turn off, confi rming fully functional operation. At this point the
system status LED fl ashes rapidly, indicating operation in TEST mode.
TEST MODE
If a positive is applied to the "ENG. TEST" terminal, TEST mode is activated: alarm
reception is blocked to make assistance easier, and the alarm memory on the fl ashing
light is reset. TEST mode is indicated by the rapid fl ashing of the system status LEDs.
TEST mode is activated for approximately 10s every time the system is switched off, a
situation detected by the "COM LED" terminal, which allows the alarm memory to be
reset automatically.
N.B. the TEST ends approximately 10s after the command at the "ENG. TEST"
terminal has been removed.
QUICK TEST
Simply connect a battery to the siren: the fl ashing light and system LED come on for
approximately 2s, then the diffuser emits a steady note at full power for approximately
half a second; this procedure allows all powered parts of the siren to be checked (from
the battery to the diffuser).
SELF-PROTECTION
The housing is protected from opening and removal by means of two tamper switches: the
series of the aforementioned contacts is available at the "TAMPER" terminals.
ALARM EVENT MEMORY
The fl ashing light is activated for the entire duration of the alarm and continues until:
1) the system is deactivated
2) or a TEST signal is applied
N.B. the alarm memory can be excluded using the "BIT" jumper
SYSTEM STATUS INDICATION
An LED functioning as a system indicator is housed inside the same casing as the fl ashing
light. In addition to indicating TEST mode, during normal operation it indicates activation
status by fl ashing slowly. This indication can be controlled from the "COM LED" input and
can be confi gured by means of the "PLED" and "LED" jumpers.
ALARM GENERATION SETTINGS
ALL
DEVICE MISSING ALARM
PALL
ALL
NEGATIVE PRESENT ALARM
PALL
ALL
POSITIVE PRESENT ALARM
PALL
ALL
NEGATIVE MISSING ALARM
PALL
SYSTEM STATUS INDICATION SETTINGS
LED
POSITIVE WITH SYSTEM OFF
PLED
LED
NEGATIVE MISSING WITH SYSTEM OFF
PLED
LED
POSITIVE WITH SYSTEM ON
PLED
LED
NEGATIVE PRESENT WITH SYSTEM OFF
PLED