UK | 11 Radio-controlled operation (EnOcean)
● Set values are transferred from the master
to the slave in cycles, e.g. ventilation level,
operating mode and sensor measurements.
Data, timer and changeover times are
also transferred in cycles and the transfer
confirmed.
● If the master does not receive a response
from the slave unit within a defined time,
the unit pair affected switches to fault.
● If the slave unit doesn't receive cyclic que-
ries from the master, it switches to fault.
The faults are displayed using LED flash
code  Chapter 16.
● Once all components have been taught in,
make a note of components and installation
location (master/slave) on the sticker (
electronics cover in unit). This will make it
easier to find the assigned units later on.
PP 45 RC
Teaching in unit pairs
Determine unit pair. Then teach in the slave
ventilation unit on the master, then teach in
the radio switch and radio sensors.
1. Switch the mains fuse on.
2. Remove front cover [1] on the
units.
3. Switch the master ventilation unit (re-
ceiver) into teach-in mode by pressing
the LEARN key [16] on the master for
2 seconds. All 3 LEDs flash, teach-in
mode is activated.
Now, a teach-in telegram must be
i
received within 120 seconds or the
teach-in mode is terminated.
4. Activate teach-in mode on the slave ven-
tilation unit (transmitter). Press the LEARN
key here for 2 seconds. All 3 LEDs flash.
80
5. Switch slave unit into send-learn mode
6. Press the LEARN key on the slave (> 2 se-
The teach-in telegram is sent.
When a teach-in telegram is correctly re-
ceived, teach-in mode is exited by the receiv-
er and transmitter.
If the master unit is still in teach-in mode (3
LEDs flashing), the teach-in telegram from the
slave unit has not arrived  Repeat process.
7. Fit front cover for internal housing [1] on
8. Run function test.
DS 45 RC
1. Remove front cover [1] on the master.
2. Switch the master ventilation unit (recei-
3. Press any rocker once. The teach-in
PP 45 RC
4. Fit front cover for internal housing [1] on
5. Run function test.
Teaching in radio sensor.
1. Remove front cover [1] on the master unit.
2. Switch the master ventilation unit (recei-
– press LEARN key briefly once. The
3 LEDs on the slave flash once and then
go out (periodic process).
conds) until the LEDs on the slave briefly
light up once and then go out.
PP 45 RC
the
units such that it locks into
the safety catches. Before putting on the
front cover, the shutter must always be
open. To do this, switch on the RC unit.
Teaching-in radio switches
ver) into teach-in mode by pressing the
teach-in key [16] on the master for
2 seconds. All 3 LEDs flash, teach-in
mode is activated.
telegram is sent. Both keys
are now taught. Once teaching-in has
been successfully completed, LEARN
mode is exited.
the master unit such that it locks into the
safety catches. Before putting on the front
cover, the shutter must always be open.
To do this, briefly switch on the RC unit.
ver) into teach-in mode by pressing the
LEARN key [16] on the master for
2 seconds. All 3 LEDs flash, teach-in
mode is activated.